AJ65SBTB32-8DT

$108.90

CC-Link small type remote I / O unit (DC input / transistor output, terminal block) AJ65SBTB32-8DT


• Estimated Lead Time : In stock. Usually ships in 7-10 working days.

• Manufacturer : Mitsubishi Electric

• AJ65SBTB32-8DT

• CC-Link small type remote I / O unit (DC input / transistor output, terminal block) AJ65SBTB32-8DT

• Input specification :

• Input format : DC input (plus common type)

• Number of input points : 4 points

• Rated input voltage : DC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 26.4 V)

• Rated input current : About 7 mA

• Maximum number of simultaneous input points : 100%

• ON voltage / ON current : 14 V or more / 3.5 mA or more

• OFF voltage / OFF current : 6 V or less / 1.7 mA or less

• Input resistance : About 3.3 k惟

• Input response time OFF ??ON : 1.5 ms or less (24 VDC)

• ON ??OFF : 1.5 ms or less (24 VDC)

• Input isolation method : Photocoupler isolation

• Output format : Transistor output (sink type)

• Number of output points : 4 points

• Rated load voltage : DC 24V

• Used load voltage range : DC 19.2 to 26.4 V (ripple ratio within 5%)

• Maximum load current : 0.5 A / 1 point, 1.2 A / 1 common

• Maximum inrush current : 1.0 A less than 10 ms

• Leakage current at OFF : 0.25 mA or less

• Maximum voltage drop during ON : DC 0.3 V or less (TYP.) 0.5 A, DC 0.6 V or less (MAX.) 0.5 A

• Output response time OFF ??ON : 0.5ms or less

• ON ??OFF : 1.5 ms or less (resistance load)

• Protection function : Overload protection function, overvoltage protection function, overheat protection function

• Output section External power supply Voltage : DC 19.2 to 26.4 V (ripple ratio within 5%)

• Current : 14.6 mA or less (24 VDC, when all points are ON) External load current is not included

• Output isolation method : Photocoupler isolation

• Common method : 8 points / common (Input: terminal trapezoidal 3 wire type, output: terminal trapezoid 2 wire type)

• Withstand voltage : Between DC external terminal and ground: AC 500 V for 1 minute

• Insulation resistance : DC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 M惟 or more

• Protection grade : IP2X

• Station type : Remote I / O station

• Number of occupied stations : 1 station

• Unit power supply Voltage : DC 20.4 to 26.4 V (ripple ratio within 5%)

• Current : 45 mA or less (24 VDC, all points ON)

• External wiring connection method : Communication unit, Unit power supply unit: 7 points 2-piece terminal block (M3 screw) I / O power supply unit, input / output unit: 18 points Direct mounting terminal block (M3 screw)

• External dimensions Height (H) : 50 mm

• Width (W) : 118 mm

• Depth (D) : 40 mm

• mass : 0.18 Kg

• Operating ambient temperature : 0 to 55 掳 C

• Storage ambient temperature : -20 to 75 掳 C

• Ambient operating humidity : 10 to 90% RH, non condensing

• Storage ambient humidity : 10 to 90% RH, non condensing

• Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

• When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

• Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

• Use atmosphere : No corrosive gas

• Use elevation : 0 to 2000 m

• Installation location : In the control panel

• Over voltage category : II or less

• Pollution degree : 2 or less

• Shipping Weight : 1.2 Kg