Hero Banner

Welcome to Our Company

Explore the best products from top brands

Control & Monitoring: DCS, ESD. SCADA, HMI, PLC

All products

AJ65VBTCE2-8T

$174.60

CC-Link small type remote I / O unit (transistor output, sensor connector (e-CON)) AJ65VBTCE2-8T


• Estimated Lead Time : In stock. Usually ships in 7-10 working days.

• Manufacturer : Mitsubishi Electric

• AJ65VBTCE2-8T

• CC-Link small type remote I / O unit (transistor output, sensor connector (e-CON)) AJ65VBTCE2-8T

• Output format : Transistor output (sink type)

• Number of output points : 8 points

• Rated load voltage : DC12 / 24V

• Used load voltage range : DC 10.2 to 26.4 V (ripple ratio within 5%)

• Maximum load current : 0.1 A / 1 point, 0.8 A / 1 common

• Maximum inrush current : 0.7 A less than 10 ms

• Leakage current at OFF : 0.1 mA or less

• Maximum voltage drop during ON : DC 0.1 V or less (TYP.) 0.1 A, DC 0.2 V or less (MAX.) 0.1 A

• Output response time OFF ??ON : 1ms or less

• ON ??OFF : 1 ms or less (resistance load)

• Surge suppressor : Zener diode

• Protection function : Overload protection function, overvoltage protection function, overheat protection function

• Output section External power supply Voltage : DC 10.2 to 26.4 V (ripple ratio within 5%)

• Current : 5 mA or less (24 VDC, when all points are ON) External load current is not included

• Output common method : 8 points / common (Sensor connector (e - CON) type 2 wire type)

• Output isolation method : Photocoupler isolation

• Withstand voltage : Between DC external terminal and ground: AC 500 V for 1 minute

• Insulation resistance : DC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 M惟 or more

• Protection grade : IP 1 XB

• Station type : Remote I / O station

• Number of occupied stations : 1 station

• Unit power supply Voltage : DC 20.4 to 26.4 V (ripple ratio within 5%)

• Current : 35 mA or less (24 VDC, all points ON)

• External wiring connection method : Communication unit: One-touch connector for communication (sold separately) Unit power supply unit, I / O power supply unit: Power supply . FG one-touch connector (sold separately) Input / output unit: sensor connector (e-CON)

• communication cable : Ver.1.10 compatible CC-Link dedicated cable: FANC-110SBH, FA-CBL 200PSBH, CS-110

• External dimensions Height (H) : 100 mm

• Width (W) : 40 mm

• Depth (D) : 43.5 mm

• mass : 0.10 Kg

• Operating ambient temperature : 0 to 55 掳 C

• Storage ambient temperature : -20 to 75 掳 C

• Ambient operating humidity : 10 to 90% RH, non condensing

• Storage ambient humidity : 10 to 90% RH, non condensing

• Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

• When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

• Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

• Use atmosphere : No corrosive gas

• Use elevation : 0 to 2000 m

• Installation location : In the control panel

• Over voltage category : II or less

• Pollution degree : 2 or less