AJ65VBTCE32-16DT
$196.20
CC-Link small type remote I / O unit (DC input / transistor output, sensor connector (e-CON)) AJ65VBTCE 32-16DT
• Estimated Lead Time : In stock. Usually ships in 7-10 working days.
• Manufacturer : Mitsubishi Electric
• AJ65VBTCE32-16DT
• CC-Link small type remote I / O unit (DC input / transistor output, sensor connector (e-CON)) AJ65VBTCE 32-16DT
• Input format : DC input (plus common type)
• Number of input points : 8 points
• Rated input voltage : DC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 26.4 V)
• Rated input current : About 5 mA
• Maximum number of simultaneous input points : 100%
• ON voltage / ON current : 14 V or more / 3.5 mA or more
• OFF voltage / OFF current : 6 V or less / 1.7 mA or less
• Input resistance : About 4.7 k惟
• Input response time OFF ??ON : 1.5 ms or less (24 VDC)
• ON ??OFF : 1.5 ms or less (24 VDC)
• Input isolation method : Photocoupler isolation
• Output format : Transistor output (sink type)
• Number of output points : 8 points
• Rated load voltage : DC 24V
• Used load voltage range : DC 19.2 to 26.4 V (ripple ratio within 5%)
• Maximum load current : 0.1 A / 1 point, 0.8 A / 1 common
• Maximum inrush current : 0.7 A less than 10 ms
• Leakage current at OFF : 0.1 mA or less
• Maximum voltage drop during ON : DC 0.1 V or less (TYP.) 0.1 A, DC 0.2 V or less (MAX.) 0.1 A
• Output response time OFF ??ON : 1ms or less
• ON ??OFF : 1 ms or less (resistance load)
• Surge suppressor : Zener diode
• Protection function : Overload protection function, overvoltage protection function, overheat protection function
• Output section External power supply Voltage : DC 19.2 to 26.4 V (ripple ratio within 5%)
• Current : 5 mA or less (24 VDC, when all points are ON) External load current is not included
• Output isolation method : Photocoupler isolation
• Common method : 16 points 1 common (Input: sensor connector (e-CON) type 3 wire type, output: sensor connector (e-CON type 2 wire type)
• Withstand voltage : Between DC external terminal and ground: AC 500 V for 1 minute
• Insulation resistance : DC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 M惟 or more
• Protection grade : IP 1 XB
• Station type : Remote I / O station
• Number of occupied stations : 1 station
• Unit power supply Voltage : DC 20.4 to 26.4 V (ripple ratio within 5%)
• Current : 40 mA or less (24 VDC, all points ON)
• External wiring connection method : Communication unit: One-touch connector for communication (sold separately) Unit power supply unit, I / O power supply unit: Power supply . FG one-touch connector (sold separately) Input / output unit: sensor connector (e-CON)
• communication cable : Ver.1.10 compatible CC-Link dedicated cable: FANC-110SBH, FA-CBL 200PSBH, CS-110
• External dimensions Height (H) : 50 mm
• Width (W) : 100 mm
• Depth (D) : 45.5 mm
• mass : 0.11 Kg
• Operating ambient temperature : 0 to 55 掳 C
• Storage ambient temperature : -20 to 75 掳 C
• Ambient operating humidity : 10 to 90% RH, non condensing
• Storage ambient humidity : 10 to 90% RH, non condensing
• Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions
• When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2
• Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)
• Use atmosphere : No corrosive gas
• Use elevation : 0 to 2000 m
• Installation location : In the control panel
• Over voltage category : II or less
• Pollution degree : 2 or less
• Shipping Weight : 1.2 Kg