Hero Banner

Welcome to Our Company

Explore the best products from top brands

Control & Monitoring: DCS, ESD. SCADA, HMI, PLC

All products

FR-D720-0.2K-CHT

$174.60

FR-D720-0.2K-CHT -- Mitsubishi Electric -- Easy Small inverter FREQROL - D 700 series Three phase 200 V


• Estimated Lead Time : 7-10 Working Days

• Manufacturer : Mitsubishi Electric

• \nFR-D720-0.2K-CHT\n

• \n\nProduct series :\nFREQROL-D 700\n\n

• \n\nType :\nEasy 路 Small inverters FREQROL-D 700 series Three-phase 200V\n\n

• \n\nProduct model name :\nFR-D720-0.2K\n\n

• \n\nApplicable motor capacity (kW) :\n0.2 kW\n\n

• \n\noutput\nRated capacity (kVA) :\n0.6\n\n

• \n\nRated current (A) :\n1.4\n\n

• \n\nOverload current rating :\n150% 60 s, 200% 0.5 s (at inverse time characteristic)\n\n

• \n\nVoltage :\n3 phase 200~240V\n\n

• \n\nRegenerative braking torque :\nMaximum value 路 Allowable usage rate :\n-\n\n

• \n\nPower supply\nVoltage class :\nThree-phase 200V class\n\n

• \n\nRated input AC voltage 路 Frequency :\n3 phase 200 ~ 240 V 50 Hz / 60 Hz\n\n

• \n\nAC voltage allowable variation :\n170 to 264 V 50 Hz / 60 Hz\n\n

• \n\nFrequency tolerance variation :\n卤 5%\n\n

• \n\nPower supply equipment capacity (kVA) :\n0.7\n\n

• \n\nProtective structure (JEM 1030) :\nClosed type (IP 20), fully closed structure series is IP 40.\n\n

• \n\ncooling method :\nSelf-cooling\n\n

• \n\nApproximate mass (kg) :\n0.5\n\n

• \n\nControl specification\ncontrol method :\nSoft-PWM control / high carrier frequency PWM control (V / F control, general magnetic flux vector control, optimum excitation control can be selected)\n\n

• \n\nOutput frequency range :\n0.2 to 400 Hz\n\n

• \n\nFrequency setting resolution :\nAnalog input :\n0.06 Hz / 60 Hz (Terminal 4: 0 to 20 mA / 10 bits), 0.06 Hz / 60 Hz (Terminals 2, 4: 0 to 10 V / 10 bits), 0.12 Hz / 60 Hz (Terminals 2 and 4: 0 to 5 V /\n\n

• \n\nDigital input :\n0.01 Hz\n\n

• \n\nFrequency accuracy :\nAnalog input :\nWithin 卤 1% of maximum output frequency (25 掳C 卤 10 掳C)\n\n

• \n\nDigital input :\nWithin 0.01% of setting output frequency\n\n

• \n\nVoltage / frequency characteristics :\nBase frequency 0 to 400 Hz Optional setting, constant torque 路 reduction Torque pattern selectable\n\n

• \n\nStarting torque :\n150% or more (at 1 Hz) When slip correction is set by general-purpose magnetic flux vector control\n\n

• \n\nTorque boost :\nManual torque boost\n\n

• \n\nAcceleration / deceleration time setting :\n0.1 ~ 3600 s (Individual acceleration / deceleration setting possible), linear or S-shaped acceleration / deceleration mode selectable\n\n

• \n\nDC braking :\nOperating frequency (0 to 120 Hz), operating time (0 to 10 s), operating voltage (0 to 30%) variable\n\n

• \n\nStall prevention operation level :\nOperating current level selectable (0 to 200% variable), selectable\n\n

• \n\nTorque limit level :\nNone\n\n

• \n\nOperating specification\nDriving function :\nUpper / lower limit frequency setting, frequency jump operation, external thermal input selection, instantaneous power failure restart operation, forward / reverse rotation prevention, remote setting, second function, multi-speed operation, regeneration avoidance, slip correction, operation mode selection, offline auto tuning Function, PID control, Computer link operation (RS - 485), Optimum excitation control, Power outage stop, Speed ??smoothing control, Modbus - RTU\n\n

• \n\nFrequency setting signal :\nNumber of analog input terminals :\n2 points\n\n

• \n\nAnalog input terminal specification :\nTerminal 2: 0 to 10 V, 0 to 5 V selectable, terminal 4: 0 to 10 V, 0 to 5 V, 4 to 20 mA selectable\n\n

• \n\nDigital input :\nInput by operation panel, parameter unit, frequency setting unit selectable\n\n

• \n\nStart signal :\nIndividual normal rotation / reverse rotation, start signal self-holding input (3 wire input) selectable\n\n

• \n\ninput signal :\nNumber of terminal points (contact input) :\n5 points\n\n

• \n\nPulse train input :\nNone\n\n

• \n\nInput terminal selectable signal :\nExternal thermal input, PU - external operation switching, V / F switching, output stop, start self-holding selection, positive terminal selection, remote setting, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal Pr. 178 to Pr. 182 (input terminal function selection) arbitrary signal from the external interlock of the PU operation, PU operation, PU operation, changeover command, inverter reset, PUNET operation changeover, external-NET operation changeover, Select by\n\n

• \n\nOutput signal :\nOutput terminal (open collector output) Number of points :\n1point\n\n

• \n\nNumber of output terminals (relay output) :\n1point\n\n

• \n\nOutput terminal selectable signal :\nDuring inverter operation, frequency reached, overload alarm, output frequency detection, regenerative brake pre alarm, electronic thermal pre alarm, inverter operation ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward rotation Safety monitor output, Safety monitor output 2, Retrying, Lifetime alarm, Current average value monitor, Remote output, Minor fault output , Abnormal output, abnormal output 3, maintenance timer alarm, selected by Pr. 190, Pr. 192, Pr. 197 (output terminal function selection).\n\n

• \n\nOutput terminal selectable signal (when option is installed) :\nCan not install built-in option\n\n

• \n\nNumber of display terminal output terminals :\n1point\n\n

• \n\nDisplay meter output terminal specification :\nFM: Up to 2.4 kHz\n\n

• \n\nPulse train output :\nNone\n\n

• \n\nDisplay meter output terminal selectable signal :\nOutput frequency, Output current (steady state), Output voltage, Frequency setting value, Converter output voltage, Regenerative brake usage rate, Electronic thermal load factor, Output current peak value, Converter output voltage peak value, Reference voltage output, Motor load factor, PID Pulse train output (1440 pulses / s / full scale) is selected by Pr.54 FM terminal function selection, target value, PID measured value, output power, PID deviation, motor thermal load factor,\n\n

• \n\ndisplay\ncontrol panel :\nOperating condition :\nOutput frequency, Output current (steady state), Output voltage, Frequency set value, Integrated energization time, Actual operating time, Converter output voltage, Regenerative brake usage rate, Electronic thermal load factor, Output current peak value, Converter output voltage peak value, Motor Selectable from load factor, PID target value, PID measurement value, PID deviation, inverter input / output terminal monitor, output power, integrated power, motor thermal load factor, inverter thermal load factor, PTC thermistor resistance value\n\n

• \n\nAbnormal content :\nAbnormality content is displayed during operation of protection function, 8 times of abnormality content is memorized (output voltage, current, frequency, total energization time immediately before protection function operation)\n\n

• \n\nProtection / alarm function :\nOvercurrent during acceleration, overcurrent during deceleration, overcurrent during deceleration, overvoltage during acceleration, overvoltage during constant speed, deceleration Overvoltage, inverter protection thermal operation, motor protection thermal operation, fin overheating, At startup Output side ground fault current, output phase loss, external thermal operation, PTC thermistor operation, parameter error, PU missing occurrence, over retry count, CPU abnormality, brake transistor abnormality, inrush resistance overheat, analog input abnormality, stop due to stall prevention , Overcurrent stall prevention, Over-voltage stall prevention, PU stop, Parameter write error, Regenerative brake pre-alarm, Electronic thermal pre-alarm, Maintenance output, Undervoltage, Operation Panel lock, Password setting, Inverter resetting, Safety Stopped\n\n

• \n\nenvironment\nAmbient temperature :\n-10 掳C to + 50 掳C (no freezing) (-10 掳C to + 40 掳C when fully closed structure specifications)\n\n

• \n\nAmbient humidity :\n90% RH or less (no condensation)\n\n

• \n\nstorage temperature :\n-20 掳C to + 65 掳C\n\n

• \n\natmosphere :\nIndoor (no corrosive gas, flammable gas, oil mist, dust)\n\n

• \nGeneral-purpose three-phase 200V class Applicable motor capacity 0.2KW聽\n

• \nMitsubishi inverter's new standard pring clamp terminal (control circuit) realized high reliability and easy wiring.聽Equipped with a safety stop function, it is possible to cut emergency output with high reliability with a blocking circuit by hardware.聽\n

• \nEquipped with the best-in-class performance in the compact body General-purpose magnetic flux vector control is installed in the compact body (3.7 K or less) of the same mounting size as our FREQROL-S500 series which is the smallest inverter of the company, and 150% (3.7 K or less) High torque has been realized.聽\n

• \nFulfilling functions Suitable for fan and pump applications Excitation control 路 PID control, deceleration stop function at power outage for machine tool applications, general purpose magnetic flux vector control for food applications 路 brake resistor connection (0.4 K to 15 K) and other applications Various functions were carried.\n

• \nShipping Weight : 1.5 Kg\n