Hero Banner

Welcome to Our Company

Explore the best products from top brands

Control & Monitoring: DCS, ESD. SCADA, HMI, PLC

All products

FR-E720S-0.75K-CHT

$273.60

Mitsubishi Electric FR-E 720 S - 0.75 K - CHT


• Estimated Lead Time : In stock. Usually ships in 7-10 working days.

• Manufacturer : Mitsubishi Electric

• Product series : FREQROL-E 700

• type : Easy 路 Powerful small inverter FREQROL-E700 series Single phase 200V

• Product model name : FR-E720S-0.75K-CHT

• Applicable motor capacity (kW) : 0.75 kW

• Rated capacity (kVA)-output : 2

• Rated current (A)-output : Five

• Overload current rating-output : 150% 60 s, 200% 3 s (inverse time characteristics)

• Voltage-output : 3 phase 200 ~ 240V

• Regenerative braking torque-output Maximum value 路 Allowable usage rate-output : -

• Power supply : Voltage class : Single phase 200V class

• Power supply: Rated input AC voltage 路 Frequency : Single phase 200 to 240 V 50 Hz / 60 Hz

• Power supply : AC voltage allowable variation : 170 to 264 V 50 Hz / 60 Hz

• Power supply : Frequency tolerance variation : 卤 5%

• Power supply equipment capacity (kVA) : 2.5

• Protective structure (JEM 1030) : Closed form (IP 20)

• cooling method : Forced air cooling

• Approximate mass (kg) : 1.4

• Control specification-control method : Soft-PWM control / high carrier frequency PWM control (V / F control, advanced magnetic flux vector control, general magnetic flux vector control, optimum excitation control can be selected)

• Control specification-Output frequency range : 0.2 to 400 Hz

• Control specification-Frequency setting resolution Analog input : 0.06 Hz / 60 Hz (Terminals 4: 4 to 20 mA / 10 bits), 0.06 Hz / 60 Hz (Terminals 2, 4: 0 to 10 V / 10 bits), 0.12 Hz / 60 Hz (Terminals 2 and 4: 0 to 5 V /

• Digital input : 0.01 Hz

• Control specification-Frequency accuracy Analog input : Within 卤 0.5% of maximum output frequency (25 掳 C 卤 10 掳 C)

• Digital input : Within 0.01% of setting output frequency

• Control specification-Voltage / frequency characteristics : Base frequency 0 to 400 Hz Optional setting, constant torque 路 reduction Torque pattern selectable

• Control specification-Starting torque : 200% or more (at 0.5 Hz) 路 路 路 When advanced magnetic flux vector control is set (3.7 K or less)

• Control specification-Torque boost : Manual torque boost

• Control specification-Acceleration / deceleration time setting : 0.01 to 360 s, 0.1 to 3600 s (Individual acceleration / deceleration can be set individually), linear or S-shaped acceleration / deceleration mode selectable

• Control specification-DC braking : Operating frequency (0 to 120 Hz), operating time (0 to 10 s), operating voltage (0 to 30%) variable

• Control specification-Stall prevention operation level : Operating current level selectable (0 to 200% variable), selectable

• Control specification-Torque limit level : 0 to 200%

• Operating specification:-

• Driving function:-

• : Upper / lower limit frequency setting, frequency jump operation, external thermal input selection, instantaneous power failure restart operation, forward / reverse rotation prevention, remote setting, brake sequence, second function, multi-speed operation, warp stop control, droop control, Slide correction, operation mode selection, offline auto tuning function, PID control, computer link operation (RS - 485)

• Frequency setting signal:-

• : Number of analog input terminals : 2 points

• Frequency setting signal:-

• : Analog input terminal specification : Terminal 2: 0 to 10 V, 0 to 5 V selectable Terminal 4: 0 to 10 V, 0 to 5 V, 4 to 20 mA selectable

• Frequency setting signal:-

• : Digital input : Input by operation panel, parameter unit

• Start signal:-

• : Individual normal rotation / reverse rotation, start signal self-holding input (3 wire input) selectable

• input signal:-

• Number of terminal points (contact input) : 7 points

• Pulse train input : None

• Input terminal selectable signal : External thermal input, PU-external operation switching, V / F switching, switching from the external power supply to the external terminal, selects the multistep speed selection, remote setting, stop selection, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal, Output stop, start self-hold selection, forward rotation, reverse rotation command, inverter reset, PU-NET operation changeover, external-NET operation changeover, command right changeover, inverter operation enable signal, PU operation selected from external interlock

• Output signal:-

• Output terminal (open collector output) Number of points : 2 points

• Number of output terminals (relay output) : 1point

• Output terminal selectable signal : During inverter operation, frequency reached, overload alarm, output frequency detection, regenerative brake pre alarm, electronic thermal pre alarm, inverter operation ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward rotation Output, brake release request, fan failure, FIN overheating pre alarm, power failure deceleration, PID control operation, retrying, life alarm, current average value monitor, remote output, minor fault output, abnormal output, abnormal output 3, maintenance timer Select from alarm

• Output terminal selectable signal (when option is installed) : Output same signal as body

• Number of display terminal output terminals : 1 point

• Display meter output terminal specification : FM: Up to 2.4 kHz

• Pulse train output : None

• Display meter output terminal selectable signal : Output frequency, motor current (steady state), output voltage, frequency setting value, motor torque, converter output voltage, regenerative brake usage rate, electronic thermal load factor, output current peak value, converter output peak value, reference voltage output, motor load Select from rate, PID target value, PID measurement value, output power. Pulse train output

• display control panel-Operating condition : Output frequency, motor current (steady state), output voltage, frequency set value, integrated energization time, actual operating time, motor torque, converter output voltage, regenerative brake usage rate, electronic thermal load factor, output current peak value, converter output voltage peak Value, motor load factor, PID target value, PID measurement value, PID deviation, inverter input / output terminal monitor, input / output terminal option monitor, output power, integrated power, motor thermal load factor, inverter thermal load factor

• display control panel-Abnormal content : Abnormality content is displayed during operation of protection function, 8 times of abnormality content is memorized (output voltage, current, frequency, total energization time immediately before protection function operation)

• Protection function :Overcurrent during acceleration, overcurrent during deceleration, overcurrent during deceleration, overvoltage during acceleration, overvoltage during constant speed, deceleration Overvoltage, inverter protection thermal operation, motor protection thermal operation, fin overheating, On startup output side ground fault current, output short circuit, output open phase, external thermal operation, option error, parameter error, PU missing occurrence, over retry count, CPU abnormality, brake transistor fault, rush resistance overheat, communication fault, analog input fault , USB communication error, brake sequence error 4 to 7

• Alarm function : Fan failure, overcurrent stall prevention, overvoltage stall prevention, PU stop, parameter writing error, regenerative brake pre alarm, electronic thermal pre alarm, maintenance output, undervoltage

• Ambient temperature environment : -10 掳 C to + 50 掳 C (no freezing) (-10 掳 C to + 40 掳 C when fully closed structure specifications)

• Ambient humidity environment : 90% RH or less (no condensation)

• storage temperature environment : -20 掳 C to + 65 掳 C

• atmosphere environment : Indoor (no corrosive gas, flammable gas, oil mist, dust)

• Altitude / vibration environment : Sea level 1000 m or less 路 5.9 m / s 2 or less

• communication : RS - 485, CC - Link, LONWorks, DeviceNet, PROFIBUS - DPV 0, Modbus RTU

• Shipping Weight : 2.4 Kg