FR-E740-0.4K, 415V
$197.10
FR-E740-0.4K, 415V -- Mitsubishi Electric
_x000D_\n • Estimated Lead Time: 7-10 Working Days
_x000D_\n • Manufacturer: Mitsubishi Electric
_x000D_\n • FR-E740-0.4K, 415V
_x000D_\n • Easy and powerful compact inverter FREQROL-E700 series three-phase 400V FR-E740-0.4K
_x000D_\n • General-purpose three-phase 400V class Applicable motor capacity 0.4KW
_x000D_\n • Driving performance of small models top-level : implementation of 200% of the high torque during 0.5Hz the advanced magnetic flux vector control (3.7K or less).聽Short-time overload capability of the equipment the torque limiting function with to withstand up from the conventional model 200% 0.5 seconds to 200% for 3 seconds, became more tenaciously more powerful.
_x000D_\n • By far the operability : equipped with M dial that further improve the operability of the scroll speed as a variable.聽The USB connector to achieve the setting support by the Wizard (interactive) function of standard equipment FR Configurator from the personal computer (setup software).
_x000D_\n • 聽Enhance scalability of : digital input by the installation of the built-in options, extension of the analog output, it can respond to various types of communication, including the CC-Link.聽Control terminal can be selected according to the application by the removable terminal block.聽It was realized the scalability of high-end comparable.
_x000D_\n • Product series :FREQROL-E700
_x000D_\n • type :Easy and powerful compact inverter FREQROL-E700 series three-phase 400V
_x000D_\n • Product No. :FR-E740-0.4K
_x000D_\n • Applicable motor capacity (kW) :0.4 kW
_x000D_\n • output :Rated capacity (kVA): 1.2
_x000D_\n • Rated current (A) :1.6
_x000D_\n • Overload current rating :150% 60s, 200% 3s (inverse time characteristics)
_x000D_\n • Voltage :3-phase 380 ~ 480V
_x000D_\n • Regenerative braking torque :Maximum value and the acceptable usage
_x000D_\n • -
_x000D_\n • Power supply :Voltage class
_x000D_\n • Three-phase 400V class
_x000D_\n • Rated input AC voltage and frequency :3-phase 380 ~ 480V 50Hz / 60Hz
_x000D_\n • AC voltage allowable variation :325 ~ 528V 50Hz / 60Hz
_x000D_\n • Frequency permissible variation :卤 5%
_x000D_\n • Power supply capacity (kVA) :1.5
_x000D_\n • Protective structure (JEM 1030) :Closed form (IP20), all closed structure series will be IP40.
_x000D_\n • Cooling system :Self-cooling
_x000D_\n • Approximate Mass (kg) :1.4
_x000D_\n • Control specification :control method
_x000D_\n • Soft-PWM control / high carrier frequency PWM control (V / F control, advanced magnetic flux vector control, general-purpose magnetic flux vector control, optimum excitation control can be selected)
_x000D_\n • Output frequency range :0.2 ~ 400Hz
_x000D_\n • Frequency setting resolution :Analog input
_x000D_\n • 0.06Hz / 60Hz (terminal 2,4: 0 ~ 10V / 10bit), 0.12Hz / 60Hz (terminal 2,4: 0 ~ 5V / 9bit), 0.06Hz / 60Hz (terminal 4: 4 ~ 20mA / 10bit)
_x000D_\n • Digital input :0.01Hz
_x000D_\n • Frequency accuracy :Analog input
_x000D_\n • Within 卤 0.5% of maximum output frequency (25掳C 卤 10掳C)
_x000D_\n • Digital input :Within 0.01% of the set output frequency
_x000D_\n • Voltage / frequency characteristic :Base frequency 0 ~ 400Hz any setting possible, constant torque reduction torque pattern can be selected
_x000D_\n • Starting torque :200% more than if you set the (0.5Hz at the time) ... advanced magnetic flux vector control (3.7K or less)
_x000D_\n • Torque boost :Manual torque boost
_x000D_\n • Acceleration and deceleration time setting :0.01 ~ 360s, 0.1 ~ 3600s (acceleration and deceleration individually configurable), straight or S-shaped acceleration and deceleration mode can be selected
_x000D_\n • DC braking :Operating frequency (0 to 120 Hz), operation time (0 to 10s), the operating voltage (0-30%) Variable
_x000D_\n • Stall prevention operation level :Operating current level can be set (0 to 200% variable), presence or absence can be selected
_x000D_\n • Torque limit level :0-200%
_x000D_\n • Operation specification :Operational function
_x000D_\n • Upper and lower limit frequency setting, frequency jump operation, external thermal input selection, instantaneous power failure restart operation, forward and reverse rotation prevention, remote setting, brake sequence, second function, multi-speed operation, stop-on-contact control, droop control, regeneration avoidance, slip compensation, operation mode selection, offline auto tuning function, PID control, computer link operation (RS-485)
_x000D_\n • Frequency setting signal :Analog input terminal points: 2 points
_x000D_\n • Analog input terminal specifications :Terminal 2: 0 ~ 10V, 0 ~ 5V selectable terminal 4: 0 ~ 10V, 0 ~ 5V, 4 ~ 20mA can be selected
_x000D_\n • Digital input :Operation panel, input by the parameter unit
_x000D_\n • Start signal :Forward and reverse individual, start signal self-holding input (3-wire input) can be selected
_x000D_\n • input signal :Terminal points (contact input): 7 points
_x000D_\n • Pulse-train input :None
_x000D_\n • Input terminal selection possible signal :Multi-speed selection, remote setting, Atetome selection, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal, brake opening completion signal, external thermal input, PU- external operation switch, V / F changeover, output stop, start self-holding selection, forward selection, reverse rotation command, inverter reset, PU-NET operation switching, external -NET change operation, command rights switching, inverter operation enable signal, from the PU operation external interlock
_x000D_\n • Output signal :Output terminal (open collector output) Number: 2 points
_x000D_\n • Output terminal (relay output) Number :1 point
_x000D_\n • Output pin-selectable signal :During inverter operation, frequency arrival, overload alarm, output frequency detection, regenerative brake pre-alarm, electronic thermal pre-alarm, inverter operation ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward reverse output, brake opening request, fan failure, FIN overheating pre-alarm, during a power failure deceleration, in PID control operation, during retry, life alarm, current average value monitor, remote output, minor fault output, abnormal output, abnormal output 3, maintenance timer select from the alarm
_x000D_\n • Output pin-selectable signal (when the option is installed) :Output the same signal as the main body
_x000D_\n • Output terminal points for display meter :1 point
_x000D_\n • Output terminal specifications for display meter :FM: up to 2.4kHz
_x000D_\n • Pulse train output :None
_x000D_\n • For meter output pin-selectable signal :Output frequency, motor current (steady), output voltage, frequency setting value, the motor torque, converter output voltage, the regenerative brake duty, electronic thermal load factor, output current peak value, the converter output voltage peak value, reference voltage output, motor load select rate, PID target value, PID measured value, from the output power.聽Pulse train output
_x000D_\n • display :control panel
_x000D_\n • Operating condition
_x000D_\n • Output frequency, motor current (steady), output voltage, frequency setting value, cumulative energization time, actual operation time, motor torque, converter output voltage, the regenerative brake duty, electronic thermal load factor, output current peak value, the converter output voltage peak value, motor load factor, PID target value, PID measured value, PID deviation, the inverter input and output terminal monitor, input and output terminal option monitor, output power, integrated power, motor thermal load factor, it can be selected from the inverter thermal load factor
_x000D_\n • Abnormal contents :Display an abnormal content at the time of operation of the protection function, store the 8 doses abnormal contents (protective function just before the output voltage and current, frequency and cumulative energization time)
_x000D_\n • Protection and alarm function :<Protection> during acceleration over-current, constant speed during the over-current, over-current during deceleration, acceleration during overvoltage, constant speed during overvoltage, during deceleration overvoltage, inverter protection thermal operation, motor protection thermal operation, fin overheat, input phase failure, startup output side earth (ground) fault overcurrent, output short circuit, output phase failure, external thermal behavior, options abnormal, parameter error, PU missing generation, the number of retries over, CPU abnormal, brake transistor abnormality, inrush resistance overheat, communication error, analog input error , USB communication error, brake sequence error 4 to 7 <alarm function> fan failure, overcurrent stall prevention, overvoltage stall prevention, PU stop, parameter write error, regenerative brake pre-alarm, electronic thermal pre-alarm, maintenance output, undervoltage
_x000D_\n • environment :Ambient temperature
_x000D_\n • -10掳C ~ + 50掳C (No freezing) (-10掳C ~ + 40掳C when the total closure structure specification)
_x000D_\n • Ambient humidity :Less than 90% RH (non-condensing)
_x000D_\n • Storage temperature :-20掳C ~ + 65掳C
_x000D_\n • atmosphere :Indoor (no corrosive gas, flammable gas, oil mist, dust and dirt)
_x000D_\n • Altitude, vibration :1000m or less above sea level 5.9M 路 / S聽2聽or less
_x000D_\n • Shipping Weight : 2.4 Kg
_x000D_\n