FX2N-16EX

$68.04

Input extension block FX 2 N - 16 EX


• Estimated Lead Time : In stock. Usually ships in 7-10 working days.

• Manufacturer : Mitsubishi Electric

• FX2N-16EX

• Input extension block FX 2 N - 16 EX

• Application sequencer : FX1N, FX3G, FX2N, FX3U, FX1NC, FX3GC, FX2NC, FX3UCFX2NC - CNV - IF is required for connection to FX1NC and FX2NC. To connect to FX3GC, FX3UC, FX2NC - CNV - IF or FX3UC - 1PS - 5V is required.

• mass : 0.3 Kg

• Rated voltage : Internal power supply from the sequencer

• Input specification :

• Number of input points : 16 points

• Input connection shape : Vertical terminal block (M3 screw)

• Input format : sink

• Input signal voltage : DC 24 V 卤 10%

• Input impedance : 4.3 k惟

• Input signal current : 5 mA / 24 VDC

• Input ON sensitivity current : 3.5 mA or more

• Input OFF sensitivity current : 1.5 mA or less

• Input response time : About 10 ms

• Input signal format : No-voltage contact input NPN or open collector transistor

• Input circuit insulation : Photocoupler insulation

• Input operation display : LED on the panel when input is ON

• Input circuit configuration

• Ambient temperature : 0 to 55 掳 C. ... Operating -25 to 75 掳 C. ..... Save

• Relative humidity : 5 to 95% RH (noncondensing).... in operation

• Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2

• Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 Ten times in each of X, Y, Z directions (80 minutes in total in total) The criterion is based on IEC 61131-2

• Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2

• Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2

• Impact resistance : 147 m / s 2 , working time 11 ms, criterion for judgment three times in X, Y, Z directions by sine half-wave pulse is according to IEC 61131-2

• Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 渭s, rising 1 ns, with noise si

• tor with period of 30 to 100 Hz

• Withstand voltage : Between the input terminal of the expansion input block and the ground terminal: 500 V AC for 1 minute

• Insulation resistance : Between the input terminal of the expansion input block and the earth terminal: 500 VDC or more 5 M惟 or more with the insulation resistance meter

• Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious

• Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.

• Shipping Weight : 1.3 Kg