FX2N-16EYR
$78.12
Mitsubishi Electric FX2N-16EYR
• Estimated Lead Time : In stock. Usually ships in 7-10 working days.
• Manufacturer : Mitsubishi Electric
• FX2N-16EYR
• Output expansion block FX2N - 16EYR
• Application sequencer FX1N, FX3G, FX2N, FX3U, FX1NC, FX3GC, FX2NC, FX3UC\n<Connecting to connector type sequencer>\nFX2NC - CNV - IF is required for connection to FX1NC and FX2NC.\nTo connect to FX3GC, FX3UC, FX2NC - CNV - IF or FX3UC - 1PS - 5V is required.
• mass 0.3 kg
• Power supply specification
• Rated voltage Internal power supply from the sequencer
• Output specification
• Number of output points 16 points
• Output connection shape Vertical terminal block (M3 screw)
• Output type / format relay
• External power supply AC 250 V DC 30 V or less
• Maximum load Resistive load\nTotal load current of 2A / 1 point common per resistance load should be as follows.\n路 Output 4 points / common: 8 A or less\n路 Output 8 points / common: 8 A or less
• Maximum load Inductive load 80VA
• Minimum load DC 5 V 2 mA (reference value)
• Response time (OFF ? ON) About 10 ms
• Response time (ON ? OFF) About 10 ms
• Circuit insulation Mechanical insulation
• Output operation indication When the relay coil is energized LED on the panel is lit
• Ambient temperature 0 to 55 掳 C. 路路路 Operating -25 to 75 掳 C. 路路路路路 Save
• Relative humidity 5 to 95% RH (noncondensing) 路 路 路 路 in operation
• Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) The\ncriteria are based on IEC 61131-2
• Anti-vibration When DIN rail is installed Frequency: 57 to 150 Hz Acceleration: 4.9 m / s 2 Ten times in each of X, Y, Z directions (total of 80 minutes each) The\ncriterion is based on IEC 61131-2
• Anti-vibration Direct installation Frequency: 10 to 57 Hz One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total) The\ncriteria are based on IEC 61131-2
• Anti-vibration Direct installation Frequency: 57 to 150 Hz Acceleration: 9.8 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) The\ncriteria are based on IEC 61131-2
• Impact resistance 147 m / s 2 , working time 11 ms,\ncriterion for judgment three times in X, Y, Z directions by sine half-wave pulse is according to IEC 61131-2
• Noise immunity Noise voltage with 1,000 Vp-p, noise width 1 碌s, rising 1 ns, with noise si
• tor with period of 30 to 100 Hz
• Withstand voltage Between the output terminal (relay) and the earth terminal of the expansion output block: AC 1500 V for 1 minute
• Insulation resistance Between the output terminal (relay) and the earth terminal of the expansion output block: 5 MO or more with DC 500 V insulation resistance meter
• Use atmosphere There is no corrosive property, flammable gas, conductive dust (dust) is not serious
• Use altitude\nCan not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.
• Shipping Weight : 1.3 Kg