Control & Monitoring: DCS, ESD. SCADA, HMI, PLC

All products

FX2N-1PG-E

$311.22

Pulse output block FX 2 N - 1 PG - E


• Estimated Lead Time : In stock. Usually ships in 7-10 working days.

• Manufacturer : Mitsubishi Electric

• FX2N-1PG-E

• Pulse output block FX 2 N - 1 PG - E

• Number of control axes : Independent single axis

• Pulse output method : Open collector method

• Pulse output form : Pulse train + direction, forward rotation / reverse rotation pulse train

• Maximum frequency : 100 kHz

• Acceleration / deceleration processing : Automatic trapezoidal acceleration / deceleration

• Control unit : pulse, 渭m, 10 -4 inch, mdeg

• Positioning range : -999,999 to + 999,999 [X (position data magnification) pulse] -999,999 to + 999,999 [X (position data magnification) 渭m] -999,999 to + 999,999 [X (position data magnification) X 10 -4 inch] -999, 999,999 [X (position data magnification) mdeg] The position data magnification can be set to X 1, X 10, X 10 2 or X 10 3 in the parameter.

• Programming language : BFM can be specified directly by sequence program (FROM / TO instruction, application instruction operand)

• Position data : 1 point (set by sequence program)

• Absolute position detection (ABS current value reading) : Use sequencer's ABS command

• Number of occupied I / O points : Sequencer input / output 8 points occupation (It can count either input or output)

• Application sequencer : FX2N, FX3U, FX2NC, FX3UCFX2NC - CNV - IF is required for connection to FX2NC. To connect to FX3UC, FX2NC - CNV - IF or FX3UC - 1PS - 5V is required.

• mass : 0.3 Kg

• Power-supply voltage : DC 5 V 55 mA ( internal power supply from the sequencer) DC 24 V 卤 10% 40 mA (external power supply)

• Input specification :

• Control input : Three points (STOP, DOG, PG 0)

• Input signal voltage STOP, DOG : DC 24V

• PG 0 : DC 5 to 24 V

• Input signal format : Contact or open collector transistor

• Input signal current STOP, DOG : 7 mA

• PG 0 : 20 mA or less

• Input ON sensitivity STOP, DOG : 4.5 mA or more

• PG 0 : 4 mA or more

• Input OFF sensitivity STOP, DOG : 1.5 mA or less

• PG 0 : 0.5 mA or less

• Input capture speed DOG : 1 ms

• STOP : 4 ms

• PG 0 : 4 渭s

• Circuit insulation : Photocoupler insulation

• Input operation display : LED ON when input is ON

• Number of output points : 3 points (FP, RP, CLR)

• Output form Pulse output unit (FP / RP) : You can select forward rotation (FP) / reverse rotation (RP) or pulse (PLS) / direction (DIR).

• Clear signal (CLR) : It turns ON when homing operation is completed or when a limit switch is input. (Output pulse width: 20 ms)

• Output method : Open collector transistor output

• Rated load voltage Pulse output unit (FP / RP) : DC 5 V to 24 V (power supplied from the VIN terminal)

• Clear signal (CLR) : DC 5V to 24V

• Maximum load current Pulse output unit (FP / RP) : 20 mA or less

• Clear signal (CLR) : 20 mA or less

• VIN consumption current Pulse output unit (FP / RP) : 35 mA or less

• Output frequency : 100 kHz

• Output operation indication : LED on when output is ON

• Ambient temperature : 0 to 55 掳 C. ... Operating, -25 to 75 掳 C. ..... Save

• Relative humidity : 5 to 95% RH (noncondensing).... in operation

• Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)

• Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)

• Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)

• Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)

• Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse

• Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 渭s, rising 1 ns, with noise si

• tor with period of 30 to 100 Hz

• Withstand voltage : Between external terminals and ground terminal of PLC main unit: AC 500 V for 1 minute

• Insulation resistance : Between the external terminals collectively and the ground terminal of the programmable controller main body: 500 MV DC insulation resistance meter 5 M惟 or more

• Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious

• Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.

• Shipping Weight : 1.3 Kg