FX2N-232IF

$274.68

FX2N-232IF -- Mitsubishi Electric -- FX Series


• Estimated Lead Time : In stock. Usually ships in 5-7 working days.

• Manufacturer : Mitsubishi Electric

• Impact resistance

• Transmission standard : RS-232C compliant

• Insulation method : Photocoupler insulation

• Transmission distance : Maximum 15 m

• External device connection method : D-SUB 9 pin connector (male)

• Communication method : Full duplex bidirection

• Communication procedure : Non-procedural communication

• communication speed : [No procedure] 300/600/1200/2400/4800/9600/19200 (bps)

• Display (LED) : RD, SD, POWER

• Number of occupied I / O points : 8 points (It can count either input or output)

• Application sequencer : FX 2 NC, FX 3 U, FX 2 NC, FX 3 UC FX 2 NC - CNV - IF is connected to FX 2 NC. To connect to FX 3 UC, FX 2 NC - CNV - IF or FX 3 UC - 1 PS - 5 V is required.

• mass : 0.3 kg

• Power supply specification :

• Power supply : DC 5 V 40 mA (internal power supply from PLC) DC 24 V 卤 10% 80 mA (external power supply)

• Ambient temperature : 0 to 55 掳 C. 路路路 Operating, -25 to 75 掳 C. 路路路路路 Save

• Relative humidity : 5 to 95% RH (no condensation) 路 路 路 at operation

• Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)

• Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)

• Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)

• Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)

• 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse

• Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 碌s, rising 1 ns, with noise simulator with period of 30 to 100 Hz

• Withstand voltage : Between external terminals and ground terminal: 500 VAC for 1 minute

• Insulation resistance : Between external terminal and ground terminal: 500 MV DC 500 MO or more with insulation resistance meter

• ground : Class D grounding (grounding resistance: 100 O or less) Grounding must be dedicated ground or common ground.

• Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious

• Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.

• Shipping Weight: 2 kg