FX2N-32ER-ES/UL

$294.84

I / O expansion unit FX2N - 32ER - ES / UL


• Estimated Lead Time : In stock. Usually ships in 7-10 working days.

• Manufacturer : Mitsubishi Electric

• FX2N-32ER-ES/UL

• I / O expansion unit FX2N - 32ER - ES / UL

• Application sequencer : FX1N, FX3G, FX2N, FX3U

• mass : 0.65 Kg

• Rated voltage : AC 100 V to 240 V

• Voltage tolerance range : AC 85V ~ 264V

• Rated frequency : 50/60 Hz

• Power supply fuse : 250 V 3.15 A (3A)

• Inrush current : AC 100 V: maximum 40 A 5 ms or less AC 200 V: maximum 60 A 5 ms or less

• power consumption : 30 W

• 24 VDC service power supply : 24 VDC 250 mA or less When input / output expansion block is connected, 24 VDC service power is consumed.

• Input specification :

• Number of input points : 16 points

• Input connection shape : Removable terminal block (M3 screw)

• Input format : Sink / source

• Input signal voltage : DC 24 V 卤 10%

• Input impedance : 4.3 k惟

• Input signal current : 5 mA / 24 VDC

• Input ON sensitivity current : 3.5 mA or more

• Input OFF sensitivity current : 1.5 mA or less

• Input response time : About 10 ms

• Input signal format : Sink: no-voltage contact input or NPN open collector transistor source: no-voltage contact input or PNP open collector transistor

• Input circuit insulation : Photocoupler insulation

• Input operation display : LED on the panel when input is ON

• Number of output points : 16 points

• Output connection shape : Removable terminal block (M3 screw)

• Output type / format : relay

• External power supply : DC 30 V or less AC 240 V or less (When not compliant with CE, UL, cUL standard, AC 250 V or less)

• Maximum load Resistive load : Please set the total load current per 2A / 1 point common as follows. . Output 4 points / common: 8 A or less

• Inductive load : 80VA

• Minimum load : DC 5 V 2 mA (reference value)

• Response time OFF ??ON : About 10 ms

• ON ??OFF : About 10 ms

• Circuit insulation : Mechanical insulation

• Output operation indication : LED lit when relay coil is energized

• Ambient temperature : 0 to 55 掳 C. ... Operating -25 to 75 掳 C. ..... Save

• Relative humidity : 5 to 95% RH (noncondensing).... in operation

• Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2

• Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 Ten times in each of X, Y, Z directions (80 minutes in total in total) The criterion is based on IEC 61131-2

• Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2

• Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2

• Impact resistance : 147 m / s 2 , working time 11 ms, criterion for judgment three times in X, Y, Z directions by sine half-wave pulse is according to IEC 61131-2

• Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 渭s, rising 1 ns, with noise si

• tor with period of 30 to 100 Hz

• Withstand voltage : Between the power supply terminal (AC power supply) and the earth terminal: AC 1500 V for 1 minute 24 VDC Service power supply and between the input terminal (24 VDC) and the earth terminal: 500 V AC for 1 minute Between the output terminal (relay)

• Insulation resistance : Between each terminal and earth terminal: 500 MV DC 500 M惟 or more with an insulation resistance meter

• ground : Class D grounding (grounding resistance: 100 惟 or less)Grounding should be dedicated ground or common ground.

• Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious

• Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.

• Shipping Weight : 1.7 Kg