FX2N-8ER

$55.44

I / O expansion block FX2N - 8ER


• Estimated Lead Time : In stock. Usually ships in 7-10 working days.

• Manufacturer : Mitsubishi Electric

• FX2N-8ER

• I / O expansion block FX2N - 8ER

• Application sequencer : FX1N, FX3G, FX2N, FX3U, FX1NC, FX3GC, FX2NC, FX3UCFX2NC - CNV - IF is required for connection to FX1NC and FX2NC. To connect to FX3GC, FX3UC, FX2NC - CNV - IF or FX3UC - 1PS - 5V is required.

• mass : 0.2 Kg

• Rated voltage : Internal power supply from the sequencer

• Input specification :

• Number of input points : 4 points

• Input connection shape : Vertical terminal block (M3 screw)

• Input format : sink

• Input signal voltage : DC 24 V 卤 10%

• Input impedance : 4.3 k惟

• Input signal current : 5 mA / 24 VDC

• Input ON sensitivity current : 3.5 mA or more

• Input OFF sensitivity current : 1.5 mA or less

• Input response time : About 10 ms

• Input signal format : No-voltage contact input NPN or open collector transistor

• Input circuit insulation : Photocoupler insulation

• Input operation display : LED on the panel when input is ON

• Number of output points : 4 points

• Output connection shape : Vertical terminal block (M3 screw)

• Output type / format : relay

• External power supply : DC 30 V or less AC 240 V or less

• Maximum load Resistive load : Total load current of 2A / 1 point common per resistance load should be as follows. Output 4 points / common: 8 A or less

• Inductive load : 80VA

• Minimum load : DC 5 V 2 mA (reference value)

• Response time OFF ??ON : About 10 ms

• ON ??OFF : About 10 ms

• Circuit insulation : Mechanical insulation

• Output operation indication : When the relay coil is energized LED on the panel is lit

• Ambient temperature : 0 to 55 掳 C. ... Operating -25 to 75 掳 C. ..... Save

• Relative humidity : 5 to 95% RH (noncondensing).... in operation

• Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2

• Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 Ten times in each of X, Y, Z directions (80 minutes in total in total) The criterion is based on IEC 61131-2

• Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2

• Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2

• Impact resistance : 147 m / s 2 , working time 11 ms, criterion for judgment three times in X, Y, Z directions by sine half-wave pulse is according to IEC 61131-2

• Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 渭s, rising 1 ns, with noise si

• tor with period of 30 to 100 Hz

• Withstand voltage : Between the input terminal (24 VDC) and the earth terminal: 500 V AC for 1 min Between the output terminal (relay) and the earth terminal: AC 1500 V 1 min

• Insulation resistance : Between each terminal and earth terminal: 500 MV DC 500 M惟 or more with an insulation resistance meter

• Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious

• Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.

• Shipping Weight : 1.2 Kg