Hero Banner

Welcome to Our Company

Explore the best products from top brands

Control & Monitoring: DCS, ESD. SCADA, HMI, PLC

All products

FX3U-1PG

$220.50

Mitsubishi Electric FX3U-1PG


• Estimated Lead Time : In stock. Usually ships in 7-10 working days.

• Manufacturer : Mitsubishi Electric

• FX3U-1PG

• Pulse output block FX 3 U - 1 PG

• Number of control axes\n: 1 axis\n

• Positioning program\n: Created by sequence program\n(use direct specification of buffer memory such as FROM / TO instruction or MOV instruction)\n

• Positioning: -

• method\n: Increment, Absolute\n

• unit\n: PLS, 碌m, 10 -4 inch, mdeg\n

• Unit magnification\n: 1, 10, 100, 1000 times\n

• range\n: -2, 147, 483, 648 to 2, 147, 483, 647 PLS\n

• Speed 鈥嬧�媍ommand\n: Hz, cm / min, inch / min, 10 deg / min\n

• Output frequency\n: Output frequency 1 Hz to 200 kHz\n

• Acceleration / deceleration processing\n: Trapezoidal acceleration / deceleration: 1 to 32,767 ms\napproximate S-shaped acceleration / deceleration: 1 to 5,000 ms\n

• Start-up time\n: Motor system: 1 ms or less\nMechanical system: 2 ms or less\n

• Number of occupied I / O points\n: 8 points (It can count either input or output)\n

• Application sequencer\n:\nAbout connection to FX5U, FX5UC CPU Unit> For connection to\nFX5U, FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC are connected to FX5U, FX5U, FX3U (Ver.2.20 or later), FX3UC Is required. Depending on the system configuration, please choose either.\n\nTo connect to FX3UC, FX2NC - CNV - IF or FX3UC - 1PS - 5V is required.\n

• mass\n: About 0.2 kg\n

• Power supply specification\n:\n

• Drive power supply: -

• For input signal\n: For input signal DC 24 V 卤 10% Consumption current 40 mA or less\n

• For output signal\n: For pulse output: DC 5 to 24 V DC consumption current 35\nmA or less For CLR signal: DC 5 to 24 V DC consumption current 20 mA or less\n

• For internal control\n: DC 5 V Consumption current 150 mA\n(Power is supplied from the sequencer body via extension cable)\n

• Input specification: -

• Input signal name: -

• Group 1 STOP\n: Used for interrupt input during deceleration stop input or external command positioning, interruption 2-speed positioning operation\n

• Group 1 DOG\n: DOG type Used for interrupt input during DOG input or external command positioning during machine home return operation, interrupt 1st speed positioning, interrupt stop, interrupt 2nd speed positioning operation\n

• Group 2 PG 0\n: Zero point signal input\nDOG type Used in machine home return operation\n

• Group 1: -

• Signal voltage\n: DC 24 V (power supplied from S / S terminal)\n

• Input current\n: 7.0 mA\n

• ON current\n: 4.5 mA or more\n

• OFF current\n: 1.5 mA or less\n

• Signal type\n: No-voltage contact input At\nsink input: NPN open collector transistor\nSource input: PNP open collector transistor\n

• Response time\n: DOG input: 1 ms\nSTOP input: 4 ms\n

• Circuit insulation\n: Photocoupler insulation\n

• Input operation display\n: LED ON when input is ON\n

• Group 2: -

• Signal voltage\n: DC 5 to 24 V\n

• Input current\n: 20 mA or less\n

• ON current\n: 4.0 mA or more\n

• OFF current\n: 0.5 mA or less\n

• Signal type\n: NPN open collector transistor\n

• Response pulse width\n: 4 碌s or more\n

• Circuit insulation\n: Photocoupler insulation\n

• Input operation display\n: LED ON when input is ON\n

• Output specification\n:\n

• Output signal name: -

• Group 1 FP\n: Forward pulse or pulse train\n

• RP\n: Reverse rotation pulse or rotation direction signal\n

• Group 2 CLR\n: CLR signal\n

• Group 1: -

• Output format\n: A transistor\n

• Output method\n: You can select forward rotation pulse (FP) / reverse rotation pulse (RP) or pulse (PLS) / direction (DIR)\n

• Output frequency\n: 1 Hz to 200 kHz\n

• Rated load voltage\n: DC 5 to 24 V\n

• Maximum load current\n: 20 mA or less\n

• VIN consumption current\n: DC 5 to 24 V 35 mA or less\n

• Output ON voltage\n: Below 1.0V\n

• Output operation indication\n: LED on when output is ON\n

• Group 2: -

• Output format\n: A transistor\n

• Output method\n: Pulse (output pulse width: 20 ms)\n

• Rated load voltage\n: DC 5 to 24 V\n

• Maximum load current\n: 20 mA or less\n

• Output ON voltage\n: 1.5V or less\n

• Output operation indication\n: LED on when output is ON\n

• Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz\n: One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)\n

• Anti-vibration When DIN rail is installed Frequency: 57 to 150 Hz\n: Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)\n

• Anti-vibration Direct installation Frequency: 10 to 57 Hz\n: One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)\n

• Anti-vibration Direct installation Frequency: 57 to 150 Hz\n: Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)\n

• Impact resistance\n: 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse\n

• Noise immunity\n: Noise voltage with 1,000 Vp-p, noise width 1 碌s, rising 1 ns, with noise si

• tor with period of 30 to 100 Hz\n

• Withstand voltage\n: Between all terminals and ground terminal: 500 VAC for 1 minute\n

• Insulation resistance\n: Between all terminals and ground terminal: 500 MV DC 500 MO or more with an insulation resistance meter\n

• Use atmosphere\n: There is no corrosive property, flammable gas, conductive dust (dust) is not serious\n

• Use altitude\n:\nCan not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.\n

• Shipping Weight : 1.2 Kg