FX3U-2HSY-ADP

$463.68

High speed output adapter FX 3 U - 2 HSY - ADP


• Estimated Lead Time : In stock. Usually ships in 7-10 working days.

• Manufacturer : Mitsubishi Electric

• FX3U-2HSY-ADP

• High speed output adapter FX 3 U - 2 HSY - ADP

• Number of control axes : Independent 2 axes (2 units connected and independent 4 axes controllable)

• Pulse output method : Differential line driver system

• Pulse output form : Pulse train + direction, forward rotation / reverse rotation pulse train

• Maximum frequency : 200 kHz

• Acceleration / deceleration processing : Depending on the sequence program

• Control unit : pulse

• Positioning range : Depending on the sequence program

• Programming language : Sequence program

• Position data : 1 point (set by sequence program)

• Absolute position detection (ABS current value reading) : Use sequencer's ABS command

• Number of occupied I / O points : When connecting one FX 3 U - 2 HSY - ADP, use the outputs Y000, Y001, Y004, Y005 of the basic unit. In the case of connecting two units, use the outputs Y000 to Y007 of the basic unit.

• Application sequencer : FX3U

• mass : 0.08 Kg

• Power-supply voltage : DC 5 V 30 mA ( internal power supply from the sequencer ) DC 24 V 60 mA ( internal power supply from the service power supply of the sequencer)

• Number of output points : When 4 points are connected: Y000, Y001, Y004, Y005 are assigned. When two units are connected: Y000 to Y007 are assigned. (FX 3 U - 2 HSY - ADP Output terminals of the sequencer body with the same number can not be used.)

• Output form : You can select forward rotation (FP) / reverse rotation (RP) or pulse (PLS) / direction (DIR).

• Output method : Differential line driver output

• Output frequency : 200 kHz

• Operation indication : LED on when output is ON

• Ambient temperature : 0 to 55 掳 C. ... Operating, -25 to 75 掳 C. ..... Save

• Relative humidity : 5 to 95% RH (noncondensing).... in operation

• Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)

• Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)

• Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)

• Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)

• Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse

• Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 渭s, rising 1 ns, with noise si

• tor with period of 30 to 100 Hz

• Withstand voltage : High-speed output Between the output terminal of the special adapter and the earth terminal of the PLC main unit: AC 500 V for 1 minute

• Insulation resistance : High-speed output Between the output terminal of the special adapter and the earth terminal of the programmable controller main body: 500 MV DC, 5 M惟 or more with the insulation resistance meter

• Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious

• Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.

• Shipping Weight : 1 Kg