FX3U-485-BD
$36.54
Extension board for RS - 485 communication FX3U - 485 - BD
• Estimated Lead Time : In stock. Usually ships in 7-10 working days.
• Manufacturer : Mitsubishi Electric
• FX3U-485-BD
• Extension board for RS - 485 communication FX3U - 485 - BD
• Transmission standard : RS-485 standard, RS-422 standard compliant
• Insulation method : Non-insulated (communication line and CPU)
• Transmission distance : Maximum 50 m
• External device connection method : European type terminal block
• Communication method : Half duplex bi-directional
• Communication procedure : No protocol, computer link (dedicated protocol format 1, dedicated protocol type 4), parallel link, simple PC link, inverter communication
• communication speed No procedure, computer link : 300/600/1200/2400/4800/9600/19200 (bps)
• Parallel link : 115200 (bps)
• Simple PC link : 38400 (bps)
• Inverter communication : 4800/9600/19200 (bps)
• Display (LED) : RD, SD
• Number of occupied I / O points : 0 point (It does not relate to the maximum input / output point number of the sequencer)
• Application sequencer : FX3U, FX3UC-32MT-LT (-2)
• Power supply : DC 5 V 40 mA (internal power supply from the sequencer)
• Ambient temperature : 0 to 55 掳 C. ... Operating, -25 to 75 掳 C. ..... Save
• Relative humidity : 5 to 95% RH (noncondensing).... in operation
• Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)
• Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)
• Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)
• Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)
• Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse
• Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 渭s, rising 1 ns, with noise si
• tor with period of 30 to 100 Hz
• Withstand voltage : Non-insulated between communication line and PLC main unit (Do not perform withstand voltage test)
• Insulation resistance : Non-insulated between the communication line and the programmable controller (Do not conduct insulation resistance test)
• Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious
• Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.
• Shipping Weight : 2 Kg