FX3U-485ADP

$121.50

Mitsubishi Electric FX3U-485ADP


• Estimated Lead Time: 5-7 Working Days

• Manufacturer: Mitsubishi Electric

• FX3U-485ADP

• FX3U-485ADP-MB FX3U-485ADP-MB

• Transmission standard: RS-485 standard, conform to the RS-422 standard

• Insulation method:Photocoupler

• Transmission distance: The total length 500m or less聽

(to the equipment to be connected FX2N-485-BD, FX1N- 485-BD, FX3U-485-BD,聽following the total length 50m if it contains a FX3G-485-BD)

• External device connection method: Europe terminal block

• Communication system: Half-duplex bi-directional

• Communication procedure: . MODBUS (master or slave)聽- No-protocol communication, computer link (dedicated protocol format 1, dedicated protocol format 4), parallel link聽and simple PC-to-PC link inverter communication

• communication speed MODBUS communication: 300/600/1200/2400/4800/9600/19200/38400/57600/115200 (bps)聽

corresponds to 38400/57600 / 115200bps from products manufactured on or after July 2012.聽(Serial number: 127 **** or later)

• No-protocol, the computer link: 300/600/1200/2400/4800/9600/19200/38400 (Bps)聽

FX3U, FX3UC is, later Ver.2.41, it supports 38400bps.

• Parallel link: 115200 (bps)

• Simple PC-to-PC link: 38400 (bps)

• Inverter communication: 4800/9600/19200/38400 (Bps)聽

FX3U, FX3UC is, later Ver.2.41, it supports 38400bps.

• Display (LED): RD, SD, POWER

• O occupied points: 0 points (no relation to the maximum input and output points of the sequencer)

• Apply sequencer: [FX3S]聽

V1.00 and later: corresponding to all the communication function聽

• [FX3G]聽

V1.00 and later: MODBUS, corresponding to the communication functions other than the inverter communication聽

V1.10 and later: inverter communication function to the corresponding聽

V1.30 and later: in MODBUS communication function correspondence聽

• [FX3U]聽

V2.20 and later: communication functions other than the MODBUS communication to the corresponding聽

V2.40 and later: corresponds to the MODBUS communication function聽

• [FX3GC]聽

V1.40 and later: corresponding to all the communication function聽

• [FX3UC]聽

V1.00 and later: MODBUS communication communication function to the corresponding non-聽

V2.40 and later: corresponds to the MODBUS communication function.

• connection to FX3S is required FX3S-CNV-ADP.聽

• Connection to the FX3G is required FX3G-CNV-ADP.聽

• FX3U, connection to the FX3UC-32MT-LT (-2), you must have the function expansion board.

• mass: 0.08kg

• Power Specifications:

• Power supply: DC5V 20mA (internal power supply from the sequencer)

• Ambient temperature: 0 ~ 55 掳C ..... operation, -25 ~ 75 掳C ..... during storage

• Relative humidity: 5 ~ 95% RH (non-condensing) ...... operation

• Vibration resistance When the DIN rail mounting : Frequency: 10 ~ 57Hz: Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes)

• When the DIN rail mounting : Frequency: 57 ~ 150Hz: Acceleration: 4.9m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes)

• Direct mounting at the time : Frequency: 10 ~ 57Hz: Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes)

• Direct mounting at the time : Frequency: 57 ~ 150Hz: Acceleration: 9.8m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes)

• Impact: 147m / s2, duration of action 11ms, X at half-sine pulse, Y, Z directions 3 times each

• Anti-noise: Noise voltage 1,000Vp-p, noise width 1渭s, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator

• Withstand voltage: External terminals and between the PLC main unit of the ground terminal: AC500V 1 minute

• Insulation resistance: External terminals and between the PLC main unit of the ground terminal: DC500V 5M惟 more in insulation resistance tester

• Use atmosphere: Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly

• Advanced use: 2000m or less聽can not be used in the pressurized environment to more than atmospheric pressure.聽

• There is a possibility of failure.

• Shipping Weight : 1 Kg