FX3U-485ADP-MB
$113.40
Mitsubishi Electric FX3U-485ADP-MB
• Estimated Lead Time: 5-7 Working Days
• Manufacturer: Mitsubishi Electric
• FX3U-485ADP-MB
• Transmission standard: RS-485 standard, conform to the RS-422 standard
• Insulation method:Photocoupler
• Transmission distance: The total length 500m or less聽
(to the equipment to be connected FX2N-485-BD, FX1N- 485-BD, FX3U-485-BD,聽following the total length 50m if it contains a FX3G-485-BD)
• External device connection method: Europe terminal block
• Communication system: Half-duplex bi-directional
• Communication procedure: . MODBUS (master or slave)聽- No-protocol communication, computer link (dedicated protocol format 1, dedicated protocol format 4), parallel link聽and simple PC-to-PC link inverter communication
• communication speed MODBUS communication: 300/600/1200/2400/4800/9600/19200/38400/57600/115200 (bps)聽
corresponds to 38400/57600 / 115200bps from products manufactured on or after July 2012.聽(Serial number: 127 **** or later)
• No-protocol, the computer link: 300/600/1200/2400/4800/9600/19200/38400 (Bps)聽
FX3U, FX3UC is, later Ver.2.41, it supports 38400bps.
• Parallel link: 115200 (bps)
• Simple PC-to-PC link: 38400 (bps)
• Inverter communication: 4800/9600/19200/38400 (Bps)聽
FX3U, FX3UC is, later Ver.2.41, it supports 38400bps.
• Display (LED): RD, SD, POWER
• O occupied points: 0 points (no relation to the maximum input and output points of the sequencer)
• Apply sequencer: [FX3S]聽
V1.00 and later: corresponding to all the communication function聽
• [FX3G]聽
V1.00 and later: MODBUS, corresponding to the communication functions other than the inverter communication聽
V1.10 and later: inverter communication function to the corresponding聽
V1.30 and later: in MODBUS communication function correspondence聽
• [FX3U]聽
V2.20 and later: communication functions other than the MODBUS communication to the corresponding聽
V2.40 and later: corresponds to the MODBUS communication function聽
• [FX3GC]聽
V1.40 and later: corresponding to all the communication function聽
• [FX3UC]聽
V1.00 and later: MODBUS communication communication function to the corresponding non-聽
V2.40 and later: corresponds to the MODBUS communication function.
• connection to FX3S is required FX3S-CNV-ADP.聽
• Connection to the FX3G is required FX3G-CNV-ADP.聽
• FX3U, connection to the FX3UC-32MT-LT (-2), you must have the function expansion board.
• mass: 0.08kg
• Power Specifications:
• Power supply: DC5V 20mA (internal power supply from the sequencer)
• Ambient temperature: 0 ~ 55 掳C ..... operation, -25 ~ 75 掳C ..... during storage
• Relative humidity: 5 ~ 95% RH (non-condensing) ...... operation
• Vibration resistance When the DIN rail mounting : Frequency: 10 ~ 57Hz: Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes)
• When the DIN rail mounting : Frequency: 57 ~ 150Hz: Acceleration: 4.9m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes)
• Direct mounting at the time : Frequency: 10 ~ 57Hz: Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes)
• Direct mounting at the time : Frequency: 57 ~ 150Hz: Acceleration: 9.8m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes)
• Impact: 147m / s2, duration of action 11ms, X at half-sine pulse, Y, Z directions 3 times each
• Anti-noise: Noise voltage 1,000Vp-p, noise width 1渭s, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator
• Withstand voltage: External terminals and between the PLC main unit of the ground terminal: AC500V 1 minute
• Insulation resistance: External terminals and between the PLC main unit of the ground terminal: DC500V 5M惟 more in insulation resistance tester
• Use atmosphere: Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly
• Advanced use: 2000m or less聽can not be used in the pressurized environment to more than atmospheric pressure.聽
• There is a possibility of failure.
• Shipping Weight : 1 Kg