FX3UC-16MR / DS-T

$312.30

FX3UC Series FX3UC-16MR / DS-T -- Mitsubishi Electric -- DC power supply / DC input type, input: 8 points 24V DC Sink / source, output: 8 points Relay


• Estimated Lead Time : In stock. Usually ships in 7-10 working days

• Manufacturer : Mitsubishi Electric

• Arithmetic control method : Stored program repetitive operation method (dedicated LSI), with interrupt function

• Input / output control method : Batch processing method (when executing END instruction), I / O refresh instruction, pulse catch function available

• Programming language : Relay symbol method + step ladder method (SFC expression possible)

• Program memory Maximum memory capacity : 64000 steps including 64000 step comments and file register

• Internal memory size and format : 64000 steps (compatible with source information storeable Ver. 3.00 or more) / RAM memory (back up with built-in lithium battery) Battery life: about 5 years

• Memory cassette (option) : [Ver. 3.00 or more] ??FX3U-FLROM-1M (2000/4000/8000/16000/32000/64000 steps available with loader function, source information can be stored in dedicated area 1300 kbyte) [Ver 2.20 or more] ??FX3U -FLROM-64L (with 2000/4000/8000/16000/32000/64000 steps available with loader function) , FX3U-FLROM-64 (with 2000/4000/8000/16000/32000/64000 steps available, without loader function) , FX3U -FLROM-16 (2000/4000/8000/16000 step compatible available without loader function) [less than Ver. 2.20] -FX3U-FLROM-64 (2000/4000/8000/16000/32000/64000 step compatible supported without loader function)

• Write function during RUN : Yes (program change is possible during sequencer RUN)

• Protection function : Password protection function (by keyword function)

• Real time clock Clock function : Built-in 1980 to 2079 (with leap year correction) 2 digits / 4 digits switchable, monthly difference 卤 45 seconds (25 掳 C)

• Instruction type Basic instruction : [Ver.2.30 or more] 路 29 sequence instructions 路 2 step ladder instructions [less than Ver.2.30] 路 27 sequence instructions 路 2 step ladder instructions

• Arithmetic processing speed Basic instruction : 0.065 渭s / instruction

• Applied instruction : 0.642 渭s to several 100 渭s / instruction

• Number of input and output points Number of input points : [Ver 2.20 or more] (1) 248 points or less (when using extension) (1) + (2) Total: 256 points or less FX3UC-32 MT-LT (-2) will be 240 points [Ver 2.20 Less than] (4) 240 points or less (at the time of extension combined use) (4) + (5) total: 256 points or less

• Output points : [Ver.2.20 or more] (2) 248 points or less (when using extension) (1) + (2) Total: 256 points or less FX3UC-32MT-LT (-2) will be 240 points [Ver 2.20 Less than] (5) 240 points or less (at the time of extension combined use) (4) + (5) total: 256 points or less

• Remote I / O points CC-Link : (3) 256 points or less (224 points or less when using FX2N-16CCL-M) ? The total of CC-Link, AnyWire Bitty, and AnyWire ASLINK remote I / O is 256 points or less

• AnyWire Bitty : (3) 128 points or less ? The total of remote I / O of CC-Link, AnyWire Bitty, and AnyWire ASLINK is 256 points or less

• AnyWireASLINK : (3) 128 points or less ? The total of remote I / O of CC-Link, AnyWire Bitty, and AnyWire ASLINK is 256 points or less

• AS-i : (3) 248 points or less

• Total points : [Ver 2.20 or more] (1) + (2) + (3) Total: 384 points or less (when using extension) [less than Ver 2.20] (4) + (5) total: 256 points or less (when using extension)

• device Input / output relay Input relay : X000 to X367 248 points (octal number) at the time of combined use

• Output relay : Y000 to Y367 248 points (in octal numbers) when used in combination

• Auxiliary relay General use : M0 to M499 It is possible to change the keep / non-keep setting by 500 points parameter.

• For keeping : M500 ~ M1023 524 point parameter can be used to change the keep / non-keep setting.

• For keeping (battery backup fixed area) : M1024 to M7679 6656 points Battery backup is a fixed area. The area characteristic can not be changed.

• Special use : M8000 to M8511 512 points

• State Initial state : You can change the keep / non-keep setting by the S0 to S9 10-point parameter.

• General use : S10 to S499 It is possible to change the keep / non-keep setting by 490 points parameter.

• 1 for keep : S500 to S899 The keep / non-keep setting can be changed by the 400-point parameter.

• For ananchators : S900 to S999 You can change the keep / non-keep setting by the 100-point parameter.

• 2 for keep : S1000 to S4095 3096 points battery backup fixed area. The area characteristic can not be changed.

• Timer (on delay) 100 ms : T0 to T191 192 points (0.1 to 3,276.7 seconds)

• 100 ms (for subroutines and interrupt routines) : T192 to T199 8 points (0.1 to 3,276.7 seconds)

• 10 ms : T200 to T245 46 points (0.01 to 327.67 seconds)

• 1 ms integration type : T246 to T249 4 points (0.001 to 32.767 seconds) This is a battery backup fixed area. The area characteristic can not be changed.

• 100ms integral type : T250 to T255 6 points (0.1 to 3,276.7 seconds) This is a battery backup fixed area. The area characteristic can not be changed.

• 1 ms : T256 to T511 256 points (0.001 to 32.767 seconds)

• counter 16 bit up : C0 to C99 The keep / non-keep setting can be changed by the 100 point (0 to 32,767 counts) parameter.

• 16 bit up (keep) : C100 to C199 The keep / non-keep setting can be changed by the 100 points (0 to 32,767 counts) parameter.

• 32-bit up / down : C200 to C219 The keep / non-keep setting can be changed by the 20 points (-2, 147, 483, 648 to +2, 147, 483, 647 counts) parameter.

• 32-bit up / down (keep) : C220 to C234 The keep / non-keep setting can be changed by 15 points (from 2,147,483,648 to +2,147,483,647) parameters.

• High speed counter : [32-bit high-speed up / down (keep)] Up to 8 points can be used in C235-C255 -Hardware counter 1 phase: 100 kHz, 10 kHz 2 phases: 50 kHz (1 multiplication), 50 kHz (4 multiplication) -Software counter 1 phase: There are restrictions on the number of points that can be used and the input frequency depending on the conditions of 40 kHz 2 phase: 40 kHz (1 multiplication) and 10 kHz (4 multiplication) .

• Data register (32 bits by using pair) 16-bit general purpose : D0 to D199 The keep / non-keep setting can be changed by the 200-point parameter.

• For 16 bit keep : D200-D511 You can change the keep / non-keep setting by the 312 point parameter.

• For 16-bit keep (file register) : D512 to D7999 7488 points (since D1000, the file register can be set in units of 500 points) This is a battery backup fixed area. The area characteristic can not be changed.

• 16-bit special use : D8000 to D8511 512 points

• For 16-bit index : V0 to V7, Z0 to Z7 16 points

• Extension register : [16 bits] R0 to R32767 32768 points Battery backup fixed area. The area characteristic can not be changed.

• Extended file register : [16 bits] ER0 to ER32767 Available only when 32768 memory cassettes are installed.

• Pointer For JUMP, CALL branch : P0 to P4095 4096 points (CJ instruction, CALL instruction, P63 for END jump)

• Input interrupt, input delay interrupt : I00 ? to I50 ? 6 points

• Timer interrupt : I6 ?? to I8 ?? 3 points

• Counter interrupt : I010 to I060 6 points (for HSCS instruction)

• nesting : [For master control] N0 to N7 8 points (for MC instruction)

• constant Decimal number (K) : 16 bits: -32,768 to +32,767 32 bits:-2,147,483,648 to +2,147,483,647

• Hexadecimal (H) : 16 bits: 0 to FFFF 32 bits: 0 to FFFFFFFF

• Real number (E) : 32 bits: -1.0 脳 2 128 to -1.0 脳 2 -126 , 0, 1.0 脳 2 -126 to 1.0 脳 2 128 decimal point representation and exponent representation are possible

• String ("") : Specify with the characters enclosed by "". You can use up to 32 one-byte characters in the instruction constant

• Power supply specification :

• Rated voltage : DC24V

• Voltage tolerance : DC24V -15%, + 20% Ripple (pp) within 5% The specification of the voltage range changes depending on the system configuration.

• Allowable instantaneous blackout time : Operation continues for an instantaneous power failure of 5 ms or less.

• Power supply fuse : 125V 3.15A

• Inrush current : Up to 30A 0.5ms / DC 24V

• power consumption : Power consumption changes depending on the 6W system configuration.

• Power supply for DC5V internal supply : 600 mA

• Internal power supply for CC-Link / LT network : -

• Input specification :

• Number of input points : 8 points

• Input connection shape : European terminal block

• Input format : Sink / source

• Input signal voltage : DC24V -15%, + 20% Ripple (pp) within 5%

• Input impedance X000 to X007 : [X000 to X005] 3.9 k惟 [X006, X007] 3.3 k惟

• X010 or later : -

• Input signal current X000 to X007 : [X000-X005] 6 mA / DC 24 V [X 006, X 007] 7 mA / DC 24 V

• X010 or later : -

• Input ON sensitivity current X000 to X007 : [X000 to X005] 3.5 mA or more [X006, X007] 4.5 mA or more

• X010 or later : -

• Input OFF sensitivity current : 1.5 mA or less

• Input response time : About 10 ms X000 to X017 (up to the built-in number of the basic unit) has a built-in digital filter, which can be changed from 0 to 60 ms in 1 ms steps by the application instruction or D8020. If it is set to 0, it will be as follows. X 000 to X 005: 5 渭s X 006, X 007: 50 渭s

• Input signal format : No-voltage contact input sink input: NPN open collector transistor source input: PNP open collector transistor

• Input circuit isolation : Photocoupler insulation

• Input operation display : LED lights when input is ON

• Output specification :

• Output points : 8 points

• Output connection shape : European terminal block

• Output type / format : Relay output

• External power supply : DC30 V or less AC 240 V or less (when it is not compliant with CE, UL or cUL standard, AC 250 V or less)

• Maximum load Resistive load : When using one 2A / 1 point COM ? terminal, make the total load of 4 points or 8 points of resistance load 4A or less. When connecting two COM terminals externally, make the total load of the 8 resistance loads 8A or less.

• Inductive load : 80VA

• Minimum load : DC5V 2mA (reference value)

• Open circuit leakage current : -

• ON voltage : -

• Response time OFF ??ON : About 10 ms

• ON ??OFF : About 10 ms

• Circuit isolation : Mechanical insulation

• Output operation display : LED lights up when relay coil is energized

• Ambient temperature 0 to 55 掳 C ... at operation, -25 to 75 掳 C ... at storage

• Relative humidity 5 to 95% RH (without condensation)

• Vibration resistance When mounting DIN rail Frequency: 10 to 57 Hz Single amplitude: 0.035 mm X, Y, Z each direction 10 times (total 80 minutes each) Judgment standard is according to IEC 61131-2.

• Frequency: 57 to 150 Hz Acceleration: 4.9 m / s 2 X, Y, Z each direction 10 times (total 80 minutes each) Judgment standard is according to IEC 61131-2.

• Shock resistance 147 m / s 2 , action time 11 ms, sine half-wave pulse in X, Y, Z directions 3 times in accordance with IEC 61131-2

• Noise resistant Noise voltage: 1,000 Vp-p, noise width: 1 渭s, rise time: 1 ns, period: 30 to 100 Hz noise simulator

• Withstand voltage Between all terminals and ground terminal: AC500V 1 minute

• Insulation resistance Between all terminals and between ground terminals: 5 M惟 or more with DC 500 V insulation resistance tester

• ground Type D Grounding (Grounding resistance: 100 惟 or less) < Do not connect to a common ground with a high-power system> Connect a dedicated ground or shared ground.

• Use atmosphere Corrosive, no flammable gas, no severe conductive dust (dust)

• Use altitude It can not be used in an environment pressurized to 2000 m or less at atmospheric pressure or higher. There is a possibility of breakdown.

• Shipping Weight : 3 Kg