LC1D09BD
$28.03
LC1D09BD SCHNEIDER ELECTRIC NEW & ORIGIN
Schneider contactor -LC1D09BDC LC1-D09BDC DC24V 9A. LC1D09BD_x000D_\n_x000D_\n_x000D_\n_x000D_\nMain_x000D_\n_x000D_\n_x000D_\nrange_x000D_\nTeSys_x000D_\n_x000D_\n_x000D_\nproduct name_x000D_\nTeSys D_x000D_\n_x000D_\n_x000D_\nproduct or component type_x000D_\nContactor_x000D_\n_x000D_\n_x000D_\ndevice short name_x000D_\nLC1D_x000D_\n_x000D_\n_x000D_\ncontactor application_x000D_\nMotor control_x000D_\n_x000D_\n_x000D_\nResistive load_x000D_\n_x000D_\n_x000D_\nutilisation category_x000D_\nAC-4_x000D_\n_x000D_\n_x000D_\nAC-1_x000D_\n_x000D_\n_x000D_\nAC-3_x000D_\n_x000D_\n_x000D_\npoles description_x000D_\n3P_x000D_\n_x000D_\n_x000D_\npower pole contact composition_x000D_\n3 NO_x000D_\n_x000D_\n_x000D_\n[Ue] rated operational voltage_x000D_\nPower circuit: <= 690 V AC 25...400 Hz_x000D_\n_x000D_\n_x000D_\nPower circuit: <= 300 V DC_x000D_\n_x000D_\n_x000D_\ncontrol circuit type_x000D_\nDC standard_x000D_\n_x000D_\n_x000D_\n[Uc] control circuit voltage_x000D_\n24 V DC_x000D_\n_x000D_\n_x000D_\nauxiliary contact composition_x000D_\n1 NO + 1 NC_x000D_\n_x000D_\n_x000D_\n[Uimp] rated impulse withstand voltage_x000D_\n6 kV conforming to IEC 60947_x000D_\n_x000D_\n_x000D_\novervoltage category_x000D_\nIII_x000D_\n_x000D_\n_x000D_\nmechanical durability_x000D_\n30 Mcycles_x000D_\n_x000D_\n_x000D_\nmaximum operating rate_x000D_\n3600 cyc/h 60 掳C_x000D_\n_x000D_\n_x000D_\nComplementary_x000D_\n_x000D_\n_x000D_\ncoil technology_x000D_\nBuilt-in bidirectional peak limiting diode suppressor_x000D_\n_x000D_\n_x000D_\ntime constant_x000D_\n28 ms_x000D_\n_x000D_\n_x000D_\ninrush power in W_x000D_\n5.4 W (at 20 掳C)_x000D_\n_x000D_\n_x000D_\nhold-in power consumption in W_x000D_\n5.4 W at 20 掳C_x000D_\n_x000D_\n_x000D_\nsignalling circuit frequency_x000D_\n25...400 Hz_x000D_\n_x000D_\n_x000D_\nminimum switching current_x000D_\n5 mA for signalling circuit_x000D_\n_x000D_\n_x000D_\nminimum switching voltage_x000D_\n17 V for signalling circuit_x000D_\n_x000D_\n_x000D_\ninsulation resistance_x000D_\n> 10 MOhm for signalling circuit_x000D_\n_x000D_\n_x000D_\nEnvironment_x000D_\n_x000D_\n_x000D_\nIP degree of protection_x000D_\nIP20 front face conforming to IEC 60529_x000D_\n_x000D_\n_x000D_\nprotective treatment_x000D_\nTH conforming to IEC 60068-2-30_x000D_\n_x000D_\n_x000D_\npollution degree_x000D_\n3_x000D_\n_x000D_\n_x000D_\nambient air temperature for storage_x000D_\n-60鈥�80 掳C_x000D_\n_x000D_\n_x000D_\noperating altitude_x000D_\n0...3000 m_x000D_\n_x000D_\n_x000D_\nfire resistance_x000D_\n850 掳C conforming to IEC 60695-2-1_x000D_\n_x000D_\n_x000D_\nflame retardance_x000D_\nV1 conforming to UL 94_x000D_\n_x000D_\n_x000D_\nheight_x000D_\n77 mm_x000D_\n_x000D_\n_x000D_\nwidth_x000D_\n45 mm_x000D_\n_x000D_\n_x000D_\ndepth_x000D_\n95 mm_x000D_\n_x000D_\n_x000D_\nnet weight_x000D_\n0.48 kg_x000D_\n_x000D_\n_x000D_\n
