LY2 DC24
$10.80
LY2 DC24 -- Omron -- Bi-power Relays
• Estimated Lead Time : In stock. Usually ships in 7-10 working days
• Manufacturer : Omron
• LY2 DC24
• Bi-power Relays
• Standard type, Single, Plug-in terminal, 24 VDC 10 A (Resistive load), 110 VAC 10 A (Resistive load), Output DPDT (10 A 24 V)
• Coil ratings : 24 VDC 36.9 mA
• Contact type : DPDT
• Contact method : Single
• Contact material : Ag alloy
• Contact rated load : 110 VAC 10 A (Resistive load) 110 VAC 7.5 A (Inductive load (cos 蠁= 0.4)) 24 VDC 10 A (Resistive load) 24 VDC 5 A (Inductive load (L/R = 7 ms))
• Maximum switching current : AC: 10 A DC: 10 A
• Terminal structure : Plug-in terminal
• Product classification : Monostable relays Standard type
• Coil ratings : 24 VDC 36.9 mA
• Coil resistance : 650 惟
• Operate voltage (Set voltage) : 80 % max.
• Release voltage (Reset voltage) : 10 % min.
• Max. voltage : 110 % max. (of rated voltage)
• Power consumption : Approx. 0.9 W
• Contact type : DPDT
• Contact method : Single
• Contact material : Ag alloy
• Contact rated load : 110 VAC 10 A (Resistive load) 110 VAC 7.5 A (Inductive load (cos 蠁= 0.4)) 24 VDC 10 A (Resistive load) 24 VDC 5 A (Inductive load (L/R = 7 ms))
• Maximum switching voltage : 250 VAC 125 VDC
• Maximum switching current : AC: 10 A DC: 10 A
• Failure rate : 100 mA at 5 VDC (failure level: P Reference value) (Switching frequency of 120 operations per minute)
• Ambient temperature (Operating) : -25 to 55 掳C (with no icing or condensation)
• Ambient_humidity (Operating) : 5 to 85%RH??with no icing or condensation?
• Contact resistance : 50 m惟 max., Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 1 A
• Operating time (Set time) : 25 ms max. (The operate or release time was measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature of 23 掳C)
• Release time (Reset time) : 25 ms max. (The operate or release time was measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature of 23 掳C)
• Insulation resistance : Between coil and contacts: 100 M惟 min. (at 500 VDC) Between contacts of different polarity: 100 M惟 min. (at 500 VDC) Between contacts of same polarity: 100 M惟 min. (at 500 VDC)
• Dielectric strength : Between coil and contacts: 2000 VAC (50/60 Hz 1 min) Between contacts of different polarity: 2000 VAC (50/60 Hz 1 min) Between contacts of same polarity: 1000 VAC (50/60 Hz 1 min)
• Vibration resistance (Destruction) : 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude)
• Vibration resistance (Malfunction) : 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude)
• Shock resistance (Destruction) : 1000 m/s**2
• Shock resistance (Malfunction) : 200 m/s**2
• Endurance (Mechanical) : 100 million operations min. (switching frequency 18,000 operations/h)
• Endurance (Electrical) : 500,000 operations min. (23 掳C, switching frequency 1,800 operations/h)
• Protective structure : Closed type (cover)
• Terminal structure : Plug-in terminal
• Weight : Approx. 40 g
• Shipping Weight : 2 Kg