Q06UDVCPU

$1,462.50

MITSUBISHI PLC-Q06UDVCPU


_x000D_\n • Estimated Lead Time : 聽7 Working Days

_x000D_\n • Manufacturer : Mitsubishi Electric

_x000D_\n • Universal model high speed type QCPU: Q06UDVCPU

_x000D_\n • control method : Stored program iteration operation

_x000D_\n • Input / output control method : Refresh method_x000D_\n(Direct access input / output possible by specifying direct access input / output (DX, DY))

_x000D_\n • Programming language :- Sequence control language : Relay symbol word, logic symbolic word, MELSAP 3 (SFC), MELSAP-L, function block, structured text (ST)

_x000D_\n • Peripheral connection port : USB, Ethernet

_x000D_\n • Memory card interface : Yes (SD memory card)

_x000D_\n • processing speed :- Sequence instructions LD X 0 : 1.9 ns

_x000D_\n • MOV D 0 D 1 : 3.9 ns

_x000D_\n • Constant scan : 0.5 ~ 2000 ms (Can be set in 0.1 ms increments)

_x000D_\n • Program capacity : 60K steps (240K bytes)

_x000D_\n • Memory capacity :- Program memory (drive 0) : 240 KB

_x000D_\n • Memory card (SD) (Drive 2) : Installed SD memory card (SD / SDHC) capacity (up to 32 GB)

_x000D_\n • Standard RAM (Drive 3) When the extended SRAM cassette is not used : 768 KB

_x000D_\n • When using extended SRAM cassette : Capacity when the extended SRAM cassette is not used + capacity of the_x000D_\nextended SRAM cassette (Extended SRAM cassette can be up to 8 Mbytes)

_x000D_\n • Standard ROM (Drive 4) : 1025.5 KB

_x000D_\n • CPU shared memory QCPU standard area : 8 KB

_x000D_\n • High speed communication area between multiple CPUs : 32 KB

_x000D_\n • Maximum number of stored files :- Program memory : 124

_x000D_\n • Memory card (SD) SD : Root folder: Up to 512_x000D_\nsubdirectories: Maximum 65534

_x000D_\n • SDHC : Root folder: Maximum 65535 books_x000D_\nSubdirectory: Up to 65534 books

_x000D_\n • Standard RAM : 323 books

_x000D_\n • Standard ROM : 256

_x000D_\n • Intelligent functional unit Parameter Maximum setting number :- Initial setting : 4096 pieces

_x000D_\n • refresh : 2048 pieces

_x000D_\n • Number of program memory writes : Up to 100,000 times

_x000D_\n • Number of standard ROM writes : Up to 100,000 times

_x000D_\n • Number of input / output devices : 8192 points (X / Y 0 to 1 FFF)

_x000D_\n • Number of input / output points : 4096 points (X / Y 0 to FFF)

_x000D_\n • Number of device points :- Internal relay [M] : Default 15360 points (M0 to 15359) (changeable)

_x000D_\n • Latch relay [L] : Default 8192 points (L0 to 8191) (changeable)

_x000D_\n • Link relay [B] : Default 8192 points (B 0 to 1 FFF) (changeable)

_x000D_\n • Timer [T] : Default 2048 points (T0 ~ 2047) (shared low-speed timer / high speed timer) (changed)_x000D_\nthe low-speed timer / high speed timer is specified by the instruction_x000D_\nunit of measurement of the low-speed timer / high speed timer is set in the parameter_x000D_\n(low-speed timer: 1 ~ 1000ms , 1 ms_x000D_\nincrement, default 100 ms)(High-speed timer: 0.01 to 100 ms, 0.01 ms increments, default 10.0 ms)

_x000D_\n • Integration timer [ST] : Default 0 point (Shared for low speed integration timer / high speed integration timer) (changeable)_x000D_\nLow speed integration timer / high speed integration timer is set by_x000D_\ninstruction Set the measurement unit of low speed integration timer / high speed integration timer by parameter_x000D_\n(low speed integration timer: 1 ~ 1000 ms, 1 ms_x000D_\nincrement, default 100 ms)(High-speed integration timer: 0.01 to 100 ms, 0.01 ms increments, default 10.0 ms)

_x000D_\n • Counter [C] : Normal counter: default 1024 points (C 0 ~ 1023) (changeable)

_x000D_\n • Data register [D] : Default 22528 points (D0 to 22527) (changeable)

_x000D_\n • Extended data register [D] : Default 0 point (changeable)

_x000D_\n • Link register [W] : Default 8192 points (W 0 to 1 FFF) (changeable)

_x000D_\n • Extended link register [W] : Default 0 point (changeable)

_x000D_\n • Annunciator [F] : Default 2048 points (F0 to 2047) (changeable)

_x000D_\n • Edge relay [V] : Default 2048 points (V 0 to 2047) (Changeable)

_x000D_\n • : File register [R] When the extended SRAM cassette is not used : 32768 points (R 0 to 32767)_x000D_\nUp to 393216 points can be used by block switching

_x000D_\n • When using Q4 MCA - 1 MBS : 32768 points (R 0 ~ 32767)_x000D_\nUp to 917504 points can be used by block switching

_x000D_\n • When using Q4 MCA - 2 MBS : 32768 points (R 0 ~ 32767)_x000D_\nUp to 144,1792 points can be used by block changeover

_x000D_\n • When using Q4 MCA - 4 MBS : 32768 points (R 0 to 32767)_x000D_\nUp to 2490368 points can be used by block switching

_x000D_\n • When using Q4 MCA - 8 MBS : 32768 points (R 0 to 32767)_x000D_\nMaximum 4587520 points can be used by block switching

_x000D_\n • : File register [ZR] When the extended SRAM cassette is not used : 393216 points (ZR 0 to 393215)_x000D_\nBlockswitchingnot required

_x000D_\n • When using Q4 MCA - 1 MBS : 917504 points (ZR 0 to 917503) No_x000D_\nblockswitchingrequired

_x000D_\n • When using Q4 MCA - 2 MBS : 1441792 points (ZR 0 to 1441791)_x000D_\nBlockswitchingnot required

_x000D_\n • When using Q4 MCA - 4 MBS : 2490368 points (ZR 0 to 2490367)_x000D_\nBlockswitchingnot required

_x000D_\n • When using Q4 MCA - 8 MBS : 4587520 points (ZR 0 to 4587519)_x000D_\nBlockswitchingnot required

_x000D_\n • Link special relay [SB] : Default 2048 points (SB 0 to 7 FF) (changeable)

_x000D_\n • Link special register [SW] : Default 2048 points (SW 0 to 7 FF) (changeable)

_x000D_\n • Step relay [S] : Default 8192 points (S0 to 8191) (changeable)

_x000D_\n • Index register / general operation register [Z] : Up to 20 points (Z 0 ~ 19)

_x000D_\n • Index register [Z] (when 32-bit qualification of ZR device is specified) : Up to 10 points (Z0 to 18) (Use index register [Z] as double word)

_x000D_\n • Pointer [P] : 4096 points (P 0 ~ 4095) (Device number is fixed) Usable_x000D_\nrange of local pointer / common pointer can be set by parameter

_x000D_\n • Interrupt pointer [I] : 256 points (I 0 to 255) (the number of device points is fixed)_x000D_\nPeriodic interval of system interrupt pointer I 28 to 31 can be set by parameter (0.5 to 1000.0 ms, 0.5 ms increments)_x000D_\nDefault I 28: 100 ms, I 29: 40 ms, I 30: 20 ms , I31: 10 ms

_x000D_\n • Special relay [SM] : 2048 points (SM 0 to 2047) (the number of device points is fixed)

_x000D_\n • Special register [SD] : 2048 points (SD 0 to 2047) (the number of device points is fixed)

_x000D_\n • Function input [FX] : 16 points (FX 0 to F) (the number of device points is fixed)

_x000D_\n • Function output [FY] : 16 points (FY 0 to F) (the number of device points is fixed)

_x000D_\n • Function register [FD] : 5 points (FD 0 ~ 4) (Device number is fixed)

_x000D_\n • Link direct device : Device that directly accesses link device_x000D_\nCC-Link IE, MELSECNET / H Specific only Specifications_x000D_\n: J ?? X ??, J ?? Y ??, J ?? Y ??, J ?? W ??, J ?? B ??, J ?? SW ??, J ?? SB ??

_x000D_\n • Intelligent functional unit device : Device_x000D_\nspecificationthat directly accesses buffer memory of intelligent function moduleFormat: U ?? G ??

_x000D_\n • Latch (power outage hold) range : L 0 to 8191 (default 8192 points)_x000D_\n[latch range can be set for B, F, V, T, ST, C, D, W]

_x000D_\n • RUN / PAUSE contact : One point of each RUN / PAUSE contact can be set from X 0 to 1 FFF

_x000D_\n • Clock function : Year, month, day, hour, minute, second, day of the week (Automatic leap year discrimination)_x000D_\naccuracy: -2.97 ~ + 3.75s (. TYP + 0.39s) / d at 0 ?_x000D_\naccuracy: -2.97 ~ + 3.75s (TYP + .0.39 s) / d at 25 掳 C_x000D_\nAccuracy: -12.77 to + 2.13 s (TYP. -5.32 s) / d at 55 掳 C

_x000D_\n • Allowable momentary power failure time : Depends on power supply unit

_x000D_\n • DC 5 V Internal current consumption : 0.58 A (single CPU unit) / 0.6 A (when extended SRAM cassette is installed)

_x000D_\n • External dimensions :- Height (H) : 98 mm

_x000D_\n • Width (W) : 27.4 mm

_x000D_\n • Depth (D) : 115 mm

_x000D_\n • mass : 0.20 kg

_x000D_\n • Built-in Ethernet function section :

_x000D_\n • Transmission specification :- Data transmission speed : 100/10 Mbps

_x000D_\n • Communication mode : Full duplex / half duplex

_x000D_\n • Transmission method : Baseband

_x000D_\n • Hub and node longest distance : 100 m

_x000D_\n • Maximum number of nodes / connection 10 BASE-T : Up to 4 cascade connections

_x000D_\n • 100 BASE-TX : Maximum 2 cascade connections

_x000D_\n • Number of connections : Socket communication, MELSOFT connection, MC protocol total 16 pieces_x000D_\n1 for FTP

_x000D_\n • CC-Link IE Field Network Basic Performance Specification :

_x000D_\n • 1 Number of network connections :- Master station : One

_x000D_\n • Slave station : 16 units

_x000D_\n • Number of occupied stations of slave stations : 1 to 4 stations

_x000D_\n • Maximum number of links per network :- RX : 1024 points

_x000D_\n • RY : 1024 points

_x000D_\n • RWr : 512 points

_x000D_\n • RWw : 512 points

_x000D_\n • Maximum number of links per station :- : Master station RX : 1024 points

_x000D_\n • RY : 1024 points

_x000D_\n • RWr : 512 points

_x000D_\n • RWw : 512 points

_x000D_\n • : Slave station RX : 64 points (occupies 1 station)_x000D_\n128 points (occupies 2 stations)_x000D_\n192 points (occupies 3 stations)_x000D_\n256 points (occupies 4 stations)

_x000D_\n • RY : 64 points (occupies 1 station)_x000D_\n128 points (occupies 2 stations)_x000D_\n192 points (occupies 3 stations)_x000D_\n256 points (occupies 4 stations)

_x000D_\n • RWr : 32 points (occupies 1 station)_x000D_\n64 points (occupies 2 stations)_x000D_\n96 points (occupies 3 stations)_x000D_\n128 points (occupies 4 stations)

_x000D_\n • RWw : 32 points (occupies 1 station)_x000D_\n64 points (occupies 2 stations)_x000D_\n96 points (occupies 3 stations)_x000D_\n128 points (occupies 4 stations)

_x000D_\n • UDP port number used for cyclic transmission : 61450

_x000D_\n • Transmission specification :- Data transmission speed : 100 Mbps

_x000D_\n • Number of cascade connection stages 100 BASE-TX : Check the manufacturer of the switching hub to be used for the number of connectable stages when using the switching hub.

_x000D_\n • Transmission path format : Star type

_x000D_\n • communication cable : Ethernet cable that meets 100BASE-TX standard

_x000D_\n • Maximum inter-station distance : Up to 100 m (conforming to ANSI / TIA / EIA - 568 - B (Category 5 e))

_x000D_\n • Total extension distance : Depends on system configuration

_x000D_\n • Shipping Weight : 2 Kg

_x000D_\n