Q13UDEHCPU

$1,809.36

Q13UDEHCPU -- Mitsubishi Electric -- Universal model QCPU


• Estimated Lead Time : In stock. Usually ships in 7-10 working days.

• Manufacturer : Mitsubishi Electric

• Q13UDEHCPU

• Universal model QCPU Q13UDEHCPU

• control method : Stored program iteration operation

• Input / output control method : Refresh method (Direct access input / output possible by specifying direct access input / output (DX, DY))

• Programming language Sequence control language : Relay symbol word, logic symbolic word, MELSAP 3 (SFC), MELSAP-L, function block, structured text (ST)

• processing speed Sequence instructions LD X 0 : 9.5 ns

• MOV D 0 D 1 : 19 ns

• Constant scan : 0.5 - 2000 ms (Can be set in 0.5 ms increments)

• Program capacity : 130K steps (520K bytes)

• Memory capacity Program memory (drive 0) : 520 KB

• Memory card (RAM) (Drive 1) : Amount of installed memory card capacity (maximum 8 Mbytes)

• Memory card (ROM) (Drive 2) : (Flash card : up to 4 Mbytes, ATA card : up to 32 Mbytes)

• Standard RAM (Drive 3) : 1024 KB

• Standard ROM (Drive 4) : 2048 KB

• CPU shared memory QCPU standard area : 8 KB

• High speed communication area between multiple CPUs : 32 KB

• Maximum number of stored files Program memory : 252 books

• Memory card (RAM) : 319 (when using Q3MEM-8 MBS)

• Memory card (ROM) Flash card : 288 books

• ATA card : 511 books

• Standard RAM : 4

• Standard ROM : 256

• Intelligent functional unit Parameter Maximum setting number Initial setting : 4096 pieces

• refresh : 2048 pieces

• Number of input / output devices : 8192 points (X / Y 0 to 1 FFF)

• Number of input / output points : 4096 points (X / Y 0 to FFF)

• Number of device points- Internal relay [M] : Default 8192 points (M0 to 8191) (changeable)

• Number of device points- Latch relay [L] : Default 8192 points (L0 to 8191) (changeable)

• Number of device points- Link relay [B] : Default 8192 points (B 0 to 1 FFF) (changeable)

• Number of device points- Timer [T] : Default 2048 points (T0 to 2047) (Shared by low-speed timer / high-speed timer) (Changeable) Low-speed timer / high- speed timer specified by instruction Low-speed timer / high-speed timer measurement unit is set by parameter (low-speed timer : 1 to 1000 ms, 1 ms increment, default 100 ms) (High-speed timer : 0.1 to 100.0 ms, 0.1 ms increments, default 10.0 ms)

• Number of device points- Integration timer [ST] : Default 0 point (Shared with low speed integration timer / high speed integration timer) (Changeable) Low speed integration timer / high speed integration timer specified by instruction Set the measurement unit of low speed integration timer / high speed integration timer by parameter (low speed integration timer : 1000 ms, 1 ms increment, default 100 ms) (High-speed integration timer : 0.1 to 100.0 ms, 0.1 ms increments, default 10.0 ms)

• Number of device points- Counter [C] : Normal counter : default 1024 points (C 0 ~ 1023) (changeable)

• Number of device points- Data register [D] : Default 12288 points (D 0 to 12287) (changeable)

• Number of device points- Extended data register [D] : Default 0 point (changeable)

• Number of device points- Link register [W] : Default 8192 points (W 0 to 1 FFF) (changeable)

• Number of device points- Extended link register [W] : Default 0 point (changeable)

• Number of device points- Annunciator [F] : Default 2048 points (F 0 to 2047) (changeable)

• Number of device points- Edge relay [V] : Default 2048 points (V 0 to 2047) (changeable)

• Number of device points- File register [R]- Standard RAM : 32768 points (R 0 ~ 32767) Up to 524288 points can be used by block switching

• Number of device points- File register [R]- SRAM card (1 Mbyte) : 32768 points (R 0 ~ 32767) Maximum 517120 points can be used by block switching

• Number of device points- File register [R]- SRAM card (2 Mbytes) : 32768 points (R 0 to 32767) Maximum 1041408 points can be used by block switching

• Number of device points- File register [R]- SRAM card (4 Mbytes) : 32768 points (R 0 ~ 32767) Up to 2087936 points can be used by block changeover

• Number of device points- File register [R]- SRAM card (8 Mbytes) : 32768 points (R 0 ~ 32767) Up to 4184064 points can be used by block changeover

• Number of device points- File register [R]- Flash card (2 Mbytes) : 32768 points (R 0 to 32767) Maximum 1041408 points can be used by block switching

• Number of device points- File register [R]- Flash card (4 Mbytes) : 32768 points (R 0 ~ 32767) Up to 2087936 points can be used by block changeover

• Number of device points- File register [ZR]- Standard RAM : 524288 points (ZR 0 to 524287) No block switching required

• Number of device points- File register [ZR]- SRAM card (1 Mbyte) : 517120 points (ZR 0 to 517119) No block switching required

• Number of device points- File register [ZR]- SRAM card (2 Mbytes) : 1041408 points (ZR 0 to 1041407) No block switching required

• Number of device points- File register [ZR]- SRAM card (4 Mbytes) : 2087936 points (ZR 0 to 2087935) Block switching not required

• Number of device points- File register [ZR]- SRAM card (8 Mbytes) : 4184064 points (ZR 0 to 4184063) Block switching not required

• Number of device points- File register [ZR]- Flash card (2 Mbytes) : 1041408 points (ZR 0 to 1041407) No block switching required

• Number of device points- File register [ZR]- Flash card (4 Mbytes) : 2087936 points (ZR 0 to 2087935) Block switching not required

• Number of device points- Link special relay [SB] : Default 2048 points (SB 0 to 7 FF) (changeable)

• Number of device points- Link special register [SW] : Default 2048 points (SW 0 to 7 FF) (changeable)

• Number of device points- Step relay [S] : Default 8192 points (S0 to 8191) (changeable)

• Number of device points- Index register / general operation register [Z] : Up to 20 points (Z 0 ~ 19)

• Number of device points- Index register [Z] (when ZR device 32-bit qualifier is specified) : Up to 10 points (Z0 to 18) (Use index register [Z] as double word)

• Number of device points- Pointer [P] : 4096 points (P 0 ~ 4095) (Number of device points fixed) Use range of local pointer / common pointer can be set by parameter

• Number of device points- Interrupt pointer [I] : 256 points (I 0 to 255) (the number of device points is fixed) Periodic interval of system interrupt pointer I 28 to 31 can be set by parameter (0.5 to 1000.0 ms, 0.5 ms increments) Default I 28 : 100 ms, I 29 : 40 ms, I 30 : 20 ms , I31 : 10 ms

• Number of device points- Special relay [SM] : 2048 points (SM 0 to 2047) (Device number is fixed)

• Number of device points- Special register [SD] : 2048 points (SD 0 to 2047) (the number of device points is fixed)

• Number of device points- Function input [FX] : 16 points (FX 0 to F) (Device number is fixed)

• Number of device points- Function output [FY] : 16 points (FY 0 to F) (the number of device points is fixed)

• Number of device points- Function register [FD] : 5 points (FD 0 ~ 4) (Device number is fixed)

• Link direct device : J □□ X □□, J □□ Y □□, J □□ SB □□, J □□ SB □□, J □□ SB □□, J □□ SW □□, J □□ SW □ Device specification form for directly accessing the link device of the network unit □

• Intelligent functional unit device : Device specification that directly accesses buffer memory of intelligent function module Format : U □□ G □□

• Latch (power outage hold) range : L 0 to 8191 (default 8192 points) [latch range can be set for B, F, V, T, ST, C, D, W]

• RUN / PAUSE contact : One point of each RUN / PAUSE contact can be set from X 0 to 1 FFF

• Clock function : Year, month, day, hour, minute, second, day of the week (leap year automatic discrimination) accuracy : -2.96 ~ + 3.74s (. TYP + 1.42s) / d at 0 ? accuracy : -3.18 ~ + 3.74s (TYP + . 1.50 s) / d at 25 掳 C. Accuracy : -13.20 to +2.12 s (TYP. -3.54 s) / d at 55 掳 C.

• Allowable momentary power failure time : Depends on power supply unit

• DC 5 V Internal current consumption : 0.49 A

• Height (H) : 98 mm

• Width (W) : 27.4 mm

• Depth (D) : 115 mm

• mass : 0.22 kg

• Built-in Ethernet function section :

• Transmission specification- Data transmission speed : 100/10 Mbps

• Transmission specification- Communication mode : Full duplex / half duplex

• Transmission specification- Transmission method : Baseband

• Transmission specification- Hub and node longest distance : 100 m

• Number of connections : Socket communication, MELSOFT connection, MC protocol total 16 pieces 1 for FTP

• Operating ambient temperature : 0 to 55 掳 C

• Storage ambient temperature : -25 to 75 掳 C (-20 to 75 掳 C when system includes AnS / A series unit)

• Ambient operating humidity : 5 to 95% RH, non condensing (10 to 90% RH when the system includes AnS / A series unit)

• Storage ambient humidity : 5 to 95% RH, non condensing (10 to 90% RH when the system includes AnS / A series unit)

• Anti-vibration-Meets JIS B 3502, IEC 61131-2- When there is intermittent vibration- : Frequency : 5 to 8.4 Hz, One amplitude : 3.5 mm Frequency : 8.4 to 150 Hz, Constant acceleration : 9.8 m / s 2 Sweep count : 10 times in X, Y, Z directions

• Anti-vibration-Meets JIS B 3502, IEC 61131-2- When there is continuous vibration- : Frequency : 5 to 8.4 Hz, One amplitude : 1.75 mm Frequency : 8.4 to 150 Hz, Constant acceleration : 4.9 m / s 2

• Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

• Use atmosphere : No corrosive gas

• Use elevation : 0 to 2000 m

• Installation location : In the control panel

• Over voltage category : II or less

• Pollution degree : 2 or less

• Device class : Class I

• Shipping Weight : 2 Kg