SHL-Q2255-01
$12.60
Omron SHL-Q2255-01
• Estimated Lead Time: 4-6 Weeks
• Manufacturer: Omron
• Shape/Structure: Enclosed Limit switches
• Service life: General type
• Operating mechanism: Snap action
• Actuator: Panel mount roller plunger
• Frequency: 50/60 Hz
• Switching mechanism: Self-reset mechanism
• Contact configuration: Single-Pole, Double-Throw type
• Contact form: SPDT
• Load: Micro load
• Ratings (AC): Non-Inductive load: Rated voltage: 125 VAC / Resistive load: 0.1 A(NC) 0.1 A(NO)
• Ratings (DC): Non-Inductive load: Rated voltage: 8 VDC / Resistive load: 0.1 A(NC) 0.1 A(NO)
Rated voltage: 14 VDC / Resistive load: 0.1 A(NC) 0.1 A(NO)
Rated voltage: 30 VDC / Resistive load: 0.1 A(NC) 0.1 A(NO)
• Inrush current: NC: 0.5 A
NO: 0.2 A
• Protective circuit: Classification of protection against electric shock: Class II (Double insulation)
Short-circuit protective device: 10 A fuse type gI or gG (IEC269)
• Ambient temperature: Operating: -10 to 80
• Ambient humidity: Operating: 35 to 95%
• Permissible operating speed: 0.1 mm/s to 0.5 m/s
• Permissible operating frequency Mechanically : 120 operations / 1 minute Max.
• Permissible operating frequency Electrically : 30 operations / 1 minute Max.
• Contact resistance: 30 mOhm Max. (Initial value)
(Measuring method is contact resistance meter.)
• Insulation resistance: Between each terminal of the same polarities: 100 M
Between live-metallic part and ground: 100 M
Between each terminal and non-live-metallic part: 100 M
(at 500 VDC Megger)
• Dielectric strength: Between each terminal of the same polarities: 600 V
Between live-metallic part and ground: 2000 V
Between each terminal and non-live-metallic part: 2000 V
(50/60 Hz for 1 min)
• Durability (Mechanically): 10,000,000 operations Min. (No load) * When operate the actuator with the specified value of the Over Travel. (No load)
(Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
• Durability (Electrically): 500,000 operations Min. (Resistive load 0.1 A at 125 VAC) * When operate the actuator with the specified value of the Over Travel. (Resistive load 0.1 A at 125 VAC)
(Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
• Pollution degree: 3 (EN60947-5-1)
• Vibration resistance (Malfunction): Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.
• Shock resistance Destruction : 1,000 m/s2
• Shock resistance Malfunction : Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2.
• Degree of protection: IEC60529 (JEM): IP67
NEMA250: Type1
• Mounting specification: Panel mounting
Side mounting
• Operating Force OF : Standard value Max. 9.81 N
• Release Force RF : Standard value Min. 1.96 N
• Pre-Travel PT : Standard value 1.5 mm Max.
• Over-Travel OT : Standard value 2 mm Min.
• Movement Differential MD : Standard value 0.5 mm Max.
• Operating Position OP : Standard value 43 +/- 0.8 mm