Control & Monitoring: DCS, ESD. SCADA, HMI, PLC

All products

SHL-Q2255-01

$12.60

Omron SHL-Q2255-01


• Estimated Lead Time: 4-6 Weeks

• Manufacturer: Omron

• Shape/Structure: Enclosed Limit switches

• Service life: General type

• Operating mechanism: Snap action

• Actuator: Panel mount roller plunger

• Frequency: 50/60 Hz

• Switching mechanism: Self-reset mechanism

• Contact configuration: Single-Pole, Double-Throw type

• Contact form: SPDT

• Load: Micro load

• Ratings (AC): Non-Inductive load: Rated voltage: 125 VAC / Resistive load: 0.1 A(NC) 0.1 A(NO)

• Ratings (DC): Non-Inductive load: Rated voltage: 8 VDC / Resistive load: 0.1 A(NC) 0.1 A(NO)

Rated voltage: 14 VDC / Resistive load: 0.1 A(NC) 0.1 A(NO)

Rated voltage: 30 VDC / Resistive load: 0.1 A(NC) 0.1 A(NO)

• Inrush current: NC: 0.5 A

NO: 0.2 A

• Protective circuit: Classification of protection against electric shock: Class II (Double insulation)

Short-circuit protective device: 10 A fuse type gI or gG (IEC269)

• Ambient temperature: Operating: -10 to 80

• Ambient humidity: Operating: 35 to 95%

• Permissible operating speed: 0.1 mm/s to 0.5 m/s

• Permissible operating frequency Mechanically : 120 operations / 1 minute Max.

• Permissible operating frequency Electrically : 30 operations / 1 minute Max.

• Contact resistance: 30 mOhm Max. (Initial value)

(Measuring method is contact resistance meter.)

• Insulation resistance: Between each terminal of the same polarities: 100 M

Between live-metallic part and ground: 100 M

Between each terminal and non-live-metallic part: 100 M

(at 500 VDC Megger)

• Dielectric strength: Between each terminal of the same polarities: 600 V

Between live-metallic part and ground: 2000 V

Between each terminal and non-live-metallic part: 2000 V

(50/60 Hz for 1 min)

• Durability (Mechanically): 10,000,000 operations Min. (No load) * When operate the actuator with the specified value of the Over Travel. (No load)

(Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)

• Durability (Electrically): 500,000 operations Min. (Resistive load 0.1 A at 125 VAC) * When operate the actuator with the specified value of the Over Travel. (Resistive load 0.1 A at 125 VAC)

(Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)

• Pollution degree: 3 (EN60947-5-1)

• Vibration resistance (Malfunction): Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.

• Shock resistance Destruction : 1,000 m/s2

• Shock resistance Malfunction : Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2.

• Degree of protection: IEC60529 (JEM): IP67

NEMA250: Type1

• Mounting specification: Panel mounting

Side mounting

• Operating Force OF : Standard value Max. 9.81 N

• Release Force RF : Standard value Min. 1.96 N

• Pre-Travel PT : Standard value 1.5 mm Max.

• Over-Travel OT : Standard value 2 mm Min.

• Movement Differential MD : Standard value 0.5 mm Max.

• Operating Position OP : Standard value 43 +/- 0.8 mm